Influence of age, training, intraoral scanner, and software version on the scan accuracy of inexperienced operators

Purpose To evaluate the effect of operator age on the scan accuracy (trueness and precision) of inexperienced operators when compared with experienced operators, and how training, intraoral scanner (IOS), and software version affect scan accuracy. Material and Methods Thirty‐four operators were sort...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of prosthodontics 2023-12, Vol.32 (S2), p.135-141
Hauptverfasser: Zarauz, Cristina, Pradíes, Guillermo Jesus, Chebib, Najla, Dönmez, Mustafa Borga, Karasan, Duygu, Sailer, Irena
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose To evaluate the effect of operator age on the scan accuracy (trueness and precision) of inexperienced operators when compared with experienced operators, and how training, intraoral scanner (IOS), and software version affect scan accuracy. Material and Methods Thirty‐four operators were sorted into groups: G1 (operators 40 years old, no experience), and G3 (experienced IOS operators). They conducted partial‐arch scans before and after a 4‐session training with two IOSs (Trios 3 and True Definition) and two software versions. These scans were compared with the reference scans obtained from conventional impressions and a laboratory scanner (IScan D103i) to evaluate trueness (mean root mean square values) and precision (standard deviation of root mean square values) with a software program (Geomagic Control X). Kruskal‐Wallis and post‐hoc Dunn's tests were used to evaluate the effect of age on the scan accuracy of inexperienced groups when compared with experienced operators, while the effect of training, IOS, and software version on scan accuracy was evaluated with Wilcoxon or Mann‐Whitney U tests (α = 0.05). Results Before training, G1 and G2 scans had similar accuracy (p ≥ 0.065). After training, G1 scans had higher accuracy when IOS data was pooled and had higher precision with TD (p ≤ 0.004). Training increased the scan accuracy (p < 0.001), while newer software increased the trueness of inexperienced operator scans (p = 0.015). Conclusions Age affected the scan accuracy of inexperienced operators after training, indicating that extended training may be required for older operators. Training increased the scan accuracy, and newer software increased the trueness of inexperienced operator scans.
ISSN:1059-941X
1532-849X
DOI:10.1111/jopr.13785