Retrofitted Concrete Bridge Columns Under Shaketable Excitation
Three 1/3-scale circular flexure-dominated, retrofitted, reinforced concrete bridge columns were studied using the University of Nevada, Reno, seismic shaketable system. Two steel jacket retrofit and one carbon fiber retrofit columns were tested and compared to a previously studied as-built column....
Gespeichert in:
Veröffentlicht in: | ACI structural journal 2005-07, Vol.102 (4), p.622-622 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Three 1/3-scale circular flexure-dominated, retrofitted, reinforced concrete bridge columns were studied using the University of Nevada, Reno, seismic shaketable system. Two steel jacket retrofit and one carbon fiber retrofit columns were tested and compared to a previously studied as-built column. The steel jacket retrofit columns showed increased capacity and ductility over the as-built but were adversely affected by low level motion and variable load path. A significant increase in capacity and ductility was observed for the carbon fiber jacket retrofit. Simple time-history analytical models can predict the performance of the columns adequately, although lap splice degradation is not well predicted. |
---|---|
ISSN: | 0889-3241 1944-7361 |
DOI: | 10.14359/14567 |