Measurement of self-diffusion coefficients in Li ionic conductors by using the short-lived radiotracer of 8Li
For the effective use of short-lived radioactive beams, soon to be available at the Tokai Radioactive Ion Accelerator Complex, the authors have developed a radiotracer method for diffusion studies in solids. The experimental test was performed by the measurement of the diffusion coefficients of Li i...
Gespeichert in:
Veröffentlicht in: | Journal of phase equilibria and diffusion 2005-09, Vol.26 (5), p.472-476 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | For the effective use of short-lived radioactive beams, soon to be available at the Tokai Radioactive Ion Accelerator Complex, the authors have developed a radiotracer method for diffusion studies in solids. The experimental test was performed by the measurement of the diffusion coefficients of Li in a sample of the compound βLiAl using an α-emitting radiotracer of 8Li (T1/2=0.84 s). It was found that the time-dependent yields of the α particles from the diffusing 8Li that was initially implanted in the sample could be used as a measure of the diffusivity of the tracer in a nondestructive way. The method was applied to measure the self-diffusion coefficients of Li in βLiGa, and for investigating how the Li diffusion in the Li ionic conductors is affected by the concentration of atomic defects (i.e., the existence of the atomic vacancies of Li and the defects in Ga sites that are replaced by Li). |
---|---|
ISSN: | 1547-7037 1863-7345 1934-7243 |
DOI: | 10.1007/s11669-005-0037-0 |