In this paper, a procedure is proposed to computer simulate the electronic noise of ionizing-radiation spectrometers. The viewpoint of the simulator is the output of the preamplifier, with or without an anti-aliasing filter, just in front of the ADC. Examples are given for the case of segmented high...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2004-08, Vol.51 (4), p.1817-1823
Hauptverfasser: Pullia, A., Riboldi, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, a procedure is proposed to computer simulate the electronic noise of ionizing-radiation spectrometers. The viewpoint of the simulator is the output of the preamplifier, with or without an anti-aliasing filter, just in front of the ADC. Examples are given for the case of segmented high purity Germanium detectors (HPGe). The method makes use of the fractional calculus basics. A software procedure provides the noisy waveform as a function of the fundamental electrical-physical parameters of the system, including: detector capacitance, detector leakage current, feedback resistor, 1/f-noise coefficient of the input transistor, temperature of the preamplifier input devices. The ADC quantization noise is also included in the simulation.