Comparison of whole body versus thoracic bioimpedance in relation to ultrafiltration volume and systolic blood pressure during hemodialysis

In contrast to whole body bioimpedance, which estimates fluid status at a single point in time, thoracic bioimpedance applied by a wearable device could enable continuous measurements. However, clinical experience with thoracic bioimpedance in patients on dialysis is limited. To test the reproducibi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of applied physiology (1985) 2023-12, Vol.135 (6), p.1330-1338
Hauptverfasser: Schoutteten, Melanie K, Lindeboom, Lucas, Brys, Astrid, Lanssens, Dorien, Smeets, Christophe J P, De Cannière, Hélène, De Moor, Bart, Peeters, Jacques, Heylen, Line, Van Hoof, Chris, Groenendaal, Willemijn, Kooman, Jeroen P, Vandervoort, Pieter M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In contrast to whole body bioimpedance, which estimates fluid status at a single point in time, thoracic bioimpedance applied by a wearable device could enable continuous measurements. However, clinical experience with thoracic bioimpedance in patients on dialysis is limited. To test the reproducibility of whole body and thoracic bioimpedance measurements and to compare their relationship with hemodynamic changes during hemodialysis, these parameters were measured pre- and end-dialysis in 54 patients during two sessions. The resistance from both bioimpedance techniques was moderately reproducible between two dialysis sessions (intraclass correlations of pre- to end-dialysis whole body and thoracic resistance between and were 0.711 [0.58-0.8] and 0.723 [0.6-0.81], respectively). There was a very high to high correlation between changes in ultrafiltration volume and changes in whole body thoracic resistance. Changes in systolic blood pressure negatively correlated to both bioimpedance techniques. Although the relationship between changes in ultrafiltration volume and changes in resistance was stronger for whole body bioimpedance, the relationship with changes in blood pressure was at least comparable for thoracic measurements. These results suggest that thoracic bioimpedance, measured by a wearable device, may serve as an interesting alternative to whole body measurements for continuous hemodynamic monitoring during hemodialysis. We examined the role of whole body and thoracic bioimpedance in hemodynamic changes during hemodialysis. Whole body and thoracic bioimpedance signals were strongly related to ultrafiltration volume and moderately, negatively, to changes in blood pressure. This work supports the further development of a wearable device measuring thoracic bioimpedance longitudinally in patients on hemodialysis. As such, it may serve as an innovative tool for continuous hemodynamic monitoring during hemodialysis in hospital or in a home-based setting.
ISSN:8750-7587
1522-1601
DOI:10.1152/japplphysiol.00600.2022