Two-phase modulation technique for three-level inverter-fed AC drives
Two-phase dipolar and unipolar modulation techniques for three-level three-phase inverters are suggested and compared with conventional three-phase pulsewidth modulation (PWM) techniques. Two-phase PWMs with 60/spl deg/ (0/spl deg/ and /spl plusmn/30/spl deg/ shift) and 120/spl deg/ cycles are inves...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on industrial electronics (1982) 2000-12, Vol.47 (6), p.1200-1211 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Two-phase dipolar and unipolar modulation techniques for three-level three-phase inverters are suggested and compared with conventional three-phase pulsewidth modulation (PWM) techniques. Two-phase PWMs with 60/spl deg/ (0/spl deg/ and /spl plusmn/30/spl deg/ shift) and 120/spl deg/ cycles are investigated from the point of view of harmonic losses, motor voltage spectra, and torque pulsations. It is shown that two-phase dipolar PWMs have no advantages in comparison with three-phase PWMs, while two-phase unipolar PWMs-in contrast with three-phase PWMs-considerably decrease the motor harmonic losses and torque pulsations in the whole motor voltage region. At the same time, the inverter neutral point control requires reversing to three-phase PWM technique for the duration of the control. |
---|---|
ISSN: | 0278-0046 1557-9948 |
DOI: | 10.1109/41.887947 |