Two-phase modulation technique for three-level inverter-fed AC drives

Two-phase dipolar and unipolar modulation techniques for three-level three-phase inverters are suggested and compared with conventional three-phase pulsewidth modulation (PWM) techniques. Two-phase PWMs with 60/spl deg/ (0/spl deg/ and /spl plusmn/30/spl deg/ shift) and 120/spl deg/ cycles are inves...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industrial electronics (1982) 2000-12, Vol.47 (6), p.1200-1211
Hauptverfasser: Halasz, S., Huu, B.T., Zakharov, A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Two-phase dipolar and unipolar modulation techniques for three-level three-phase inverters are suggested and compared with conventional three-phase pulsewidth modulation (PWM) techniques. Two-phase PWMs with 60/spl deg/ (0/spl deg/ and /spl plusmn/30/spl deg/ shift) and 120/spl deg/ cycles are investigated from the point of view of harmonic losses, motor voltage spectra, and torque pulsations. It is shown that two-phase dipolar PWMs have no advantages in comparison with three-phase PWMs, while two-phase unipolar PWMs-in contrast with three-phase PWMs-considerably decrease the motor harmonic losses and torque pulsations in the whole motor voltage region. At the same time, the inverter neutral point control requires reversing to three-phase PWM technique for the duration of the control.
ISSN:0278-0046
1557-9948
DOI:10.1109/41.887947