Test of the HISPET prototype
The test of a small version of the high spatial resolution positron emission tomograph (HISPET) is presented. The HISPET prototype consists of two 50-cm*50-cm multiwire proportional chambers with a 2-cm-thick lead-glass drift space converter. A CAMAC acquisition system connected to a MAC II computer...
Gespeichert in:
Veröffentlicht in: | IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) 1990-04, Vol.37 (2), p.817-822 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 822 |
---|---|
container_issue | 2 |
container_start_page | 817 |
container_title | IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) |
container_volume | 37 |
creator | Del Guerra, A. Bandettini, A. Conti, M. De Pascalis, G. Maiano, P. Perez Mendez, V. Rizzo, C. |
description | The test of a small version of the high spatial resolution positron emission tomograph (HISPET) is presented. The HISPET prototype consists of two 50-cm*50-cm multiwire proportional chambers with a 2-cm-thick lead-glass drift space converter. A CAMAC acquisition system connected to a MAC II computer has been set up. Experimental data with a /sup 22/Na pointlike source have been reconstructed with a 3-D filtered backprojection algorithm. A spatial resolution better than 9 mm (full width at half maximum) and a quantitation capability at +or-10% have been measured.< > |
doi_str_mv | 10.1109/23.106721 |
format | Article |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_miscellaneous_28695975</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>106721</ieee_id><sourcerecordid>28695975</sourcerecordid><originalsourceid>FETCH-LOGICAL-c304t-63d36b7219c33dec3ed1e29340dcea4c281fc6f914fddf7531d7ed49470310603</originalsourceid><addsrcrecordid>eNpNkE1LAzEQhoMouFYPXsXD4kHwsDWz-djNUUq1hYKC6zmsyYSubJu6SQ_996auB0_DMA_vPLyEXAOdAlD1WLIpUFmVcEIyEKIuQFT1KckohbpQXKlzchHCV1q5oCIjtw2GmHuXxzXmi-X727zJd4OPPh52eEnOXNsHvPqbE_LxPG9mi2L1-rKcPa0KwyiPhWSWyc_0UxnGLBqGFrBUjFNrsOWmrMEZ6RRwZ62rBANboeWKV5QlWcom5G7M9SF2Opguolkbv92iiVpKqgQ7QvcjlPS-98lab7pgsO_bLfp90GUtlVApfUIeRtAMPoQBnd4N3aYdDhqoPpakS6bHkhJ7M7IdIv7jfo8_vNZeNw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28695975</pqid></control><display><type>article</type><title>Test of the HISPET prototype</title><source>IEEE Electronic Library (IEL)</source><creator>Del Guerra, A. ; Bandettini, A. ; Conti, M. ; De Pascalis, G. ; Maiano, P. ; Perez Mendez, V. ; Rizzo, C.</creator><creatorcontrib>Del Guerra, A. ; Bandettini, A. ; Conti, M. ; De Pascalis, G. ; Maiano, P. ; Perez Mendez, V. ; Rizzo, C.</creatorcontrib><description>The test of a small version of the high spatial resolution positron emission tomograph (HISPET) is presented. The HISPET prototype consists of two 50-cm*50-cm multiwire proportional chambers with a 2-cm-thick lead-glass drift space converter. A CAMAC acquisition system connected to a MAC II computer has been set up. Experimental data with a /sup 22/Na pointlike source have been reconstructed with a 3-D filtered backprojection algorithm. A spatial resolution better than 9 mm (full width at half maximum) and a quantitation capability at +or-10% have been measured.< ></description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/23.106721</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>550601 -- Medicine-- Unsealed Radionuclides in Diagnostics ; Anodes ; CAMAC ; CAMAC SYSTEM ; COMPUTERIZED TOMOGRAPHY ; DATA ; Delay lines ; DIAGNOSTIC TECHNIQUES ; DIAGNOSTIC USES ; DRIFT TUBES ; ELEMENTS ; EMISSION COMPUTED TOMOGRAPHY ; EXPERIMENTAL DATA ; GLASS ; IMAGE PROCESSING ; IMAGE SCANNERS ; INFORMATION ; INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY ; Laboratories ; LEAD ; MEASURING INSTRUMENTS ; METALS ; MULTIWIRE PROPORTIONAL CHAMBERS ; NUMERICAL DATA ; POSITRON COMPUTED TOMOGRAPHY ; Positrons ; PROCESSING ; PROPORTIONAL COUNTERS ; Prototypes ; RADIATION DETECTORS ; RADIOLOGY AND NUCLEAR MEDICINE ; RESOLUTION ; SPATIAL RESOLUTION ; TECHNOLOGY ASSESSMENT ; Testing ; TOMOGRAPHY ; USA Councils ; USES 440101 -- Radiation Instrumentation-- General Detectors or Monitors & Radiometric Instruments</subject><ispartof>IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA), 1990-04, Vol.37 (2), p.817-822</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c304t-63d36b7219c33dec3ed1e29340dcea4c281fc6f914fddf7531d7ed49470310603</citedby><cites>FETCH-LOGICAL-c304t-63d36b7219c33dec3ed1e29340dcea4c281fc6f914fddf7531d7ed49470310603</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/106721$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>230,309,310,314,780,784,789,790,796,885,23930,23931,25140,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/106721$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttps://www.osti.gov/biblio/6609530$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Del Guerra, A.</creatorcontrib><creatorcontrib>Bandettini, A.</creatorcontrib><creatorcontrib>Conti, M.</creatorcontrib><creatorcontrib>De Pascalis, G.</creatorcontrib><creatorcontrib>Maiano, P.</creatorcontrib><creatorcontrib>Perez Mendez, V.</creatorcontrib><creatorcontrib>Rizzo, C.</creatorcontrib><title>Test of the HISPET prototype</title><title>IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA)</title><addtitle>TNS</addtitle><description>The test of a small version of the high spatial resolution positron emission tomograph (HISPET) is presented. The HISPET prototype consists of two 50-cm*50-cm multiwire proportional chambers with a 2-cm-thick lead-glass drift space converter. A CAMAC acquisition system connected to a MAC II computer has been set up. Experimental data with a /sup 22/Na pointlike source have been reconstructed with a 3-D filtered backprojection algorithm. A spatial resolution better than 9 mm (full width at half maximum) and a quantitation capability at +or-10% have been measured.< ></description><subject>550601 -- Medicine-- Unsealed Radionuclides in Diagnostics</subject><subject>Anodes</subject><subject>CAMAC</subject><subject>CAMAC SYSTEM</subject><subject>COMPUTERIZED TOMOGRAPHY</subject><subject>DATA</subject><subject>Delay lines</subject><subject>DIAGNOSTIC TECHNIQUES</subject><subject>DIAGNOSTIC USES</subject><subject>DRIFT TUBES</subject><subject>ELEMENTS</subject><subject>EMISSION COMPUTED TOMOGRAPHY</subject><subject>EXPERIMENTAL DATA</subject><subject>GLASS</subject><subject>IMAGE PROCESSING</subject><subject>IMAGE SCANNERS</subject><subject>INFORMATION</subject><subject>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</subject><subject>Laboratories</subject><subject>LEAD</subject><subject>MEASURING INSTRUMENTS</subject><subject>METALS</subject><subject>MULTIWIRE PROPORTIONAL CHAMBERS</subject><subject>NUMERICAL DATA</subject><subject>POSITRON COMPUTED TOMOGRAPHY</subject><subject>Positrons</subject><subject>PROCESSING</subject><subject>PROPORTIONAL COUNTERS</subject><subject>Prototypes</subject><subject>RADIATION DETECTORS</subject><subject>RADIOLOGY AND NUCLEAR MEDICINE</subject><subject>RESOLUTION</subject><subject>SPATIAL RESOLUTION</subject><subject>TECHNOLOGY ASSESSMENT</subject><subject>Testing</subject><subject>TOMOGRAPHY</subject><subject>USA Councils</subject><subject>USES 440101 -- Radiation Instrumentation-- General Detectors or Monitors & Radiometric Instruments</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><recordid>eNpNkE1LAzEQhoMouFYPXsXD4kHwsDWz-djNUUq1hYKC6zmsyYSubJu6SQ_996auB0_DMA_vPLyEXAOdAlD1WLIpUFmVcEIyEKIuQFT1KckohbpQXKlzchHCV1q5oCIjtw2GmHuXxzXmi-X727zJd4OPPh52eEnOXNsHvPqbE_LxPG9mi2L1-rKcPa0KwyiPhWSWyc_0UxnGLBqGFrBUjFNrsOWmrMEZ6RRwZ62rBANboeWKV5QlWcom5G7M9SF2Opguolkbv92iiVpKqgQ7QvcjlPS-98lab7pgsO_bLfp90GUtlVApfUIeRtAMPoQBnd4N3aYdDhqoPpakS6bHkhJ7M7IdIv7jfo8_vNZeNw</recordid><startdate>19900401</startdate><enddate>19900401</enddate><creator>Del Guerra, A.</creator><creator>Bandettini, A.</creator><creator>Conti, M.</creator><creator>De Pascalis, G.</creator><creator>Maiano, P.</creator><creator>Perez Mendez, V.</creator><creator>Rizzo, C.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>19900401</creationdate><title>Test of the HISPET prototype</title><author>Del Guerra, A. ; Bandettini, A. ; Conti, M. ; De Pascalis, G. ; Maiano, P. ; Perez Mendez, V. ; Rizzo, C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c304t-63d36b7219c33dec3ed1e29340dcea4c281fc6f914fddf7531d7ed49470310603</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>550601 -- Medicine-- Unsealed Radionuclides in Diagnostics</topic><topic>Anodes</topic><topic>CAMAC</topic><topic>CAMAC SYSTEM</topic><topic>COMPUTERIZED TOMOGRAPHY</topic><topic>DATA</topic><topic>Delay lines</topic><topic>DIAGNOSTIC TECHNIQUES</topic><topic>DIAGNOSTIC USES</topic><topic>DRIFT TUBES</topic><topic>ELEMENTS</topic><topic>EMISSION COMPUTED TOMOGRAPHY</topic><topic>EXPERIMENTAL DATA</topic><topic>GLASS</topic><topic>IMAGE PROCESSING</topic><topic>IMAGE SCANNERS</topic><topic>INFORMATION</topic><topic>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</topic><topic>Laboratories</topic><topic>LEAD</topic><topic>MEASURING INSTRUMENTS</topic><topic>METALS</topic><topic>MULTIWIRE PROPORTIONAL CHAMBERS</topic><topic>NUMERICAL DATA</topic><topic>POSITRON COMPUTED TOMOGRAPHY</topic><topic>Positrons</topic><topic>PROCESSING</topic><topic>PROPORTIONAL COUNTERS</topic><topic>Prototypes</topic><topic>RADIATION DETECTORS</topic><topic>RADIOLOGY AND NUCLEAR MEDICINE</topic><topic>RESOLUTION</topic><topic>SPATIAL RESOLUTION</topic><topic>TECHNOLOGY ASSESSMENT</topic><topic>Testing</topic><topic>TOMOGRAPHY</topic><topic>USA Councils</topic><topic>USES 440101 -- Radiation Instrumentation-- General Detectors or Monitors & Radiometric Instruments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Del Guerra, A.</creatorcontrib><creatorcontrib>Bandettini, A.</creatorcontrib><creatorcontrib>Conti, M.</creatorcontrib><creatorcontrib>De Pascalis, G.</creatorcontrib><creatorcontrib>Maiano, P.</creatorcontrib><creatorcontrib>Perez Mendez, V.</creatorcontrib><creatorcontrib>Rizzo, C.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection><jtitle>IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Del Guerra, A.</au><au>Bandettini, A.</au><au>Conti, M.</au><au>De Pascalis, G.</au><au>Maiano, P.</au><au>Perez Mendez, V.</au><au>Rizzo, C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Test of the HISPET prototype</atitle><jtitle>IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA)</jtitle><stitle>TNS</stitle><date>1990-04-01</date><risdate>1990</risdate><volume>37</volume><issue>2</issue><spage>817</spage><epage>822</epage><pages>817-822</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>The test of a small version of the high spatial resolution positron emission tomograph (HISPET) is presented. The HISPET prototype consists of two 50-cm*50-cm multiwire proportional chambers with a 2-cm-thick lead-glass drift space converter. A CAMAC acquisition system connected to a MAC II computer has been set up. Experimental data with a /sup 22/Na pointlike source have been reconstructed with a 3-D filtered backprojection algorithm. A spatial resolution better than 9 mm (full width at half maximum) and a quantitation capability at +or-10% have been measured.< ></abstract><cop>United States</cop><pub>IEEE</pub><doi>10.1109/23.106721</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9499 |
ispartof | IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA), 1990-04, Vol.37 (2), p.817-822 |
issn | 0018-9499 1558-1578 |
language | eng |
recordid | cdi_proquest_miscellaneous_28695975 |
source | IEEE Electronic Library (IEL) |
subjects | 550601 -- Medicine-- Unsealed Radionuclides in Diagnostics Anodes CAMAC CAMAC SYSTEM COMPUTERIZED TOMOGRAPHY DATA Delay lines DIAGNOSTIC TECHNIQUES DIAGNOSTIC USES DRIFT TUBES ELEMENTS EMISSION COMPUTED TOMOGRAPHY EXPERIMENTAL DATA GLASS IMAGE PROCESSING IMAGE SCANNERS INFORMATION INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY Laboratories LEAD MEASURING INSTRUMENTS METALS MULTIWIRE PROPORTIONAL CHAMBERS NUMERICAL DATA POSITRON COMPUTED TOMOGRAPHY Positrons PROCESSING PROPORTIONAL COUNTERS Prototypes RADIATION DETECTORS RADIOLOGY AND NUCLEAR MEDICINE RESOLUTION SPATIAL RESOLUTION TECHNOLOGY ASSESSMENT Testing TOMOGRAPHY USA Councils USES 440101 -- Radiation Instrumentation-- General Detectors or Monitors & Radiometric Instruments |
title | Test of the HISPET prototype |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T19%3A24%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Test%20of%20the%20HISPET%20prototype&rft.jtitle=IEEE%20Transactions%20on%20Nuclear%20Science%20(Institute%20of%20Electrical%20and%20Electronics%20Engineers);%20(USA)&rft.au=Del%20Guerra,%20A.&rft.date=1990-04-01&rft.volume=37&rft.issue=2&rft.spage=817&rft.epage=822&rft.pages=817-822&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/23.106721&rft_dat=%3Cproquest_RIE%3E28695975%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28695975&rft_id=info:pmid/&rft_ieee_id=106721&rfr_iscdi=true |