The evaluation of corrosion processes for engineered barrier systems
Constant-deformation SCC tests using double U-bend samples were conducted in the previously described supersaturated, deaerated PbCl^sub 2^ and Pb(NO^sub 3^)^sub 2^ solutions at 95°C. As seen in Table IV, no SCC was observed after 42 days of testing in supersaturated PbCl^sub 2^ solutions as a funct...
Gespeichert in:
Veröffentlicht in: | JOM (1989) 2005-01, Vol.57 (1), p.36-42 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Constant-deformation SCC tests using double U-bend samples were conducted in the previously described supersaturated, deaerated PbCl^sub 2^ and Pb(NO^sub 3^)^sub 2^ solutions at 95°C. As seen in Table IV, no SCC was observed after 42 days of testing in supersaturated PbCl^sub 2^ solutions as a function of fabrication effects, applied potential, and pH. |
---|---|