A novel switchable water stationary phase for supercritical fluid chromatography

A novel pH switchable water stationary phase is presented for use in supercritical fluid chromatography (SFC). By adding NH4OH to the water coating and system hydration, changes in CO2 pressure and temperature allow a wide range of stationary phase pH conditions (∼3–9) to be achieved, which impact a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2023-10, Vol.1278, p.341686, Article 341686
Hauptverfasser: Nai, Emmanuel A., Thurbide, Kevin B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A novel pH switchable water stationary phase is presented for use in supercritical fluid chromatography (SFC). By adding NH4OH to the water coating and system hydration, changes in CO2 pressure and temperature allow a wide range of stationary phase pH conditions (∼3–9) to be achieved, which impact analyte retention properties. For example, 100 atm and 50 °C produces an acidic water stationary phase (pH near 4.0) where octanoic acid readily elutes while the base caffeine does not. Conversely, at 80 atm and 120 °C a basic water stationary phase (pH near 8.0) is obtained and the opposite occurs. Further, under constant pressure and temperature conditions, simply adding or removing NH4OH from the system is also found to readily allow switching between the basic and acidic water stationary phase modes and demonstrates control over ionizable analyte elution. For instance, hexanoic acid elution is near 40 times more delayed on a basic water stationary phase and, as such, it can be eluted at later points in time as desired by removing the NH4OH and switching to an acidic stationary phase. Experiments indicate that stationary phase pH switching occurs uniformly across the 15 m column length within about 18 s and that analyte retention times are very reproducible upon performing a switch (1.4% RSD; n = 3). Results demonstrate the selectivity factor between acidic and neutral analytes can be reversed and increased about 35 times, while in other trials resolution also similarly increased near 40-fold. By rapidly switching the stationary phase pH back and forth between acidic and basic modes, the selectivity between ionizable analytes could also be increased as desired. Various applications with the system show that it can vastly increase the separation between target analytes and matrix components as required by the dynamics of a particular separation. [Display omitted] •A novel pH switchable water stationary phase introduced for SFC.•Adding a base allows for wide pH control from ∼3 to 9.•Stationary phase can be switched by temperature, pressure, or base removal.•Allows great control of analyte separations during SFC runs.
ISSN:0003-2670
1873-4324
1873-4324
DOI:10.1016/j.aca.2023.341686