High precision dynamic measurement method for axial clearance based on time division multiplexing with dispersive interferometry

Rotor-stator axial clearance is a crucial design parameter affecting rotating machines’ efficiency and safety. To accurately measure the dynamic axial clearance in high-speed machinery, a precise method based on time division multiplexing with frequency domain interferometry has been proposed. This...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics express 2023-08, Vol.31 (17), p.28549
Hauptverfasser: Duan, Fajie, Li, Xiuming, Bao, Ruijia, Fu, Xiao, Liu, Wenzheng, Yu, Zhenxin, Guo, Guanghui
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Rotor-stator axial clearance is a crucial design parameter affecting rotating machines’ efficiency and safety. To accurately measure the dynamic axial clearance in high-speed machinery, a precise method based on time division multiplexing with frequency domain interferometry has been proposed. This method has proven robust and accurate through simulations and experiments. The inclusion of an optical switch enables the utilization of dispersive interferometry(DPI) and time division multiplexing for multiple channels of the light source. It achieves a static accuracy of 1.5 µm for a 15 mm range and a dynamic accuracy of 9 µm at 3000 rpm.
ISSN:1094-4087
1094-4087
DOI:10.1364/OE.498360