Spectral mismatch in calibration of photovoltaic reference devices by global sunlight method

The state of the art for calibration of photovoltaic reference devices has been reviewed recently. In the global sunlight method the total irradiance is measured by a pyrheliometer and a shaded pyranometer while the device is held at 25DGC. The method is supposed to have high repeatability even if t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Measurement science & technology 2005-06, Vol.16 (6), p.1250-1254
Hauptverfasser: Müllejans, Harald, Ioannides, Andreas, Kenny, Robert, Zaaiman, Willem, Ossenbrink, Heinz A, Dunlop, Ewan D
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The state of the art for calibration of photovoltaic reference devices has been reviewed recently. In the global sunlight method the total irradiance is measured by a pyrheliometer and a shaded pyranometer while the device is held at 25DGC. The method is supposed to have high repeatability even if the spectral irradiance is not measured, provided that the atmospheric conditions are selected carefully. Here we investigate seasonal variation of this method by calculating the spectral mismatch for crystalline silicon reference solar cells for spectra measured at air mass of 1.5 and the defined reference spectral irradiance. A seasonal variation is found with negligible mismatch for certain periods but significant deviations for other periods. Based on this a modified global sunlight method using global natural sunlight for the calibration of photovoltaic reference devices is proposed, using measured spectral irradiance and applying mismatch correction.
ISSN:0957-0233
1361-6501
DOI:10.1088/0957-0233/16/6/002