Effectiveness of photobiomodulation with low-level lasers on the acceleration of orthodontic tooth movement: a systematic review and meta-analysis of split-mouth randomised clinical trials

Although several studies have evaluated the effect of low-level laser therapy (LLLT) on orthodontic movement acceleration, results are still inconsistent. Such inconsistencies may be attributed to the differences in the LLLT application protocols, especially in terms of wavelength ranges. Objective:...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lasers in medical science 2023-09, Vol.38 (1), p.200-200, Article 200
Hauptverfasser: Grajales, Marggie, Ríos-Osorio, Nestor, Jimenez-Peña, Oscar, Mendez-Sanchez, Juan, Sanchez-Fajardo, Kelly, García-Perdomo, Herney Andrés
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Although several studies have evaluated the effect of low-level laser therapy (LLLT) on orthodontic movement acceleration, results are still inconsistent. Such inconsistencies may be attributed to the differences in the LLLT application protocols, especially in terms of wavelength ranges. Objective: (i) to assess the clinical effects of LLLT on the acceleration of orthodontic movement and (ii) to establish the most effective LLLT wavelength to accelerate tooth movement during orthodontic treatments. MEDLINE (PubMed), Scopus, ScienceDirect, and LILACS were searched from inception to October 2022. Inclusion criteria: Split-mouth randomised clinical trials (RCTs) on systemically healthy patients reporting the effect of LLLT in accelerating orthodontic movements, specifically retraction of canines. The risk of bias was assessed using RoB-2. A random effect model was applied. Nineteen RCTs met the inclusion criteria for qualitative synthesis, and eighteen RCTs were included in the quantitative synthesis. Seventeen studies were rated as at some concerns of bias and two studies were classified as having a low risk of bias. In general terms, this systematic review and meta-analysis presents a moderate risk of bias. Findings of this systematic review and meta-analysis point to a tendency for faster orthodontic dental movement in the groups receiving LLLT treatment during the first (OR of 0.28 95% CI (0.07 to 0.48)), second (OR of 0.52 95% CI (0.31 to 0.73)), and third (OR of 0.41 95% CI (0.03 to 0.79)) month follow-up. Wavelengths ≤ 810 nm and energy density values ≤ 5.3 J/cm 2 were associated with faster orthodontic tooth movement.
ISSN:1435-604X
0268-8921
1435-604X
DOI:10.1007/s10103-023-03870-7