Boosting quantification accuracy of chemical exchange saturation transfer MRI with a spatial–spectral redundancy‐based denoising method

Chemical exchange saturation transfer (CEST) is a versatile technique that enables noninvasive detections of endogenous metabolites present in low concentrations in living tissue. However, CEST imaging suffers from an inherently low signal‐to‐noise ratio (SNR) due to the decreased water signal cause...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:NMR in biomedicine 2024-01, Vol.37 (1), p.e5027-n/a
Hauptverfasser: Chen, Xinran, Wu, Jian, Yang, Yu, Chen, Huan, Zhou, Yang, Lin, Liangjie, Wei, Zhiliang, Xu, Jiadi, Chen, Zhong, Chen, Lin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Chemical exchange saturation transfer (CEST) is a versatile technique that enables noninvasive detections of endogenous metabolites present in low concentrations in living tissue. However, CEST imaging suffers from an inherently low signal‐to‐noise ratio (SNR) due to the decreased water signal caused by the transfer of saturated spins. This limitation challenges the accuracy and reliability of quantification in CEST imaging. In this study, a novel spatial–spectral denoising method, called BOOST (suBspace denoising with nOnlocal lOw‐rank constraint and Spectral local‐smooThness regularization), was proposed to enhance the SNR of CEST images and boost quantification accuracy. More precisely, our method initially decomposes the noisy CEST images into a low‐dimensional subspace by leveraging the global spectral low‐rank prior. Subsequently, a spatial nonlocal self‐similarity prior is applied to the subspace‐based images. Simultaneously, the spectral local‐smoothness property of Z‐spectra is incorporated by imposing a weighted spectral total variation constraint. The efficiency and robustness of BOOST were validated in various scenarios, including numerical simulations and preclinical and clinical conditions, spanning magnetic field strengths from 3.0 to 11.7 T. The results demonstrated that BOOST outperforms state‐of‐the‐art algorithms in terms of noise elimination. As a cost‐effective and widely available post‐processing method, BOOST can be easily integrated into existing CEST protocols, consequently promoting accuracy and reliability in detecting subtle CEST effects. A novel spatial–spectral redundancy‐based denoising method, called BOOST, was proposed to boost quantification accuracy for CEST MRI in low‐SNR conditions. The results demonstrated that BOOST outperforms state‐of‐the‐art algorithms in terms of noise elimination, consequently promoting accuracy and reliability in detecting subtle CEST effects.
ISSN:0952-3480
1099-1492
DOI:10.1002/nbm.5027