Purpose There is considerable variability among surgeons regarding the type of mesh used in ventral hernia repair. There has been an increasing incidence of mesh fractures with lightweight (LW) and mediumweight (MW) meshes. However, HW mesh has been associated with a greater foreign body sensation a...
Gespeichert in:
Veröffentlicht in: | Hernia : the journal of hernias and abdominal wall surgery 2024-04, Vol.28 (2), p.291-300 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
There is considerable variability among surgeons regarding the type of mesh used in ventral hernia repair. There has been an increasing incidence of mesh fractures with lightweight (LW) and mediumweight (MW) meshes. However, HW mesh has been associated with a greater foreign body sensation and chronic pain. This meta-analysis aims to compare the outcomes of HW and non-heavyweight (NHW) meshes in ventral hernia repair.
Methods
We systematically reviewed the PubMed, Embase, Cochrane, and Scopus databases to identify studies comparing HW with NHW meshes in hernia repair. Outcomes analyzed included hernia recurrence, seroma, hematoma, foreign body sensation, postoperative pain, and wound infection. We performed two subgroup analyses focusing on randomized controlled trials and open retromuscular repairs. Statistical analysis was performed using RevMan 5.4.
Results
We screened 1704 studies. Nine studies were finally included in this meta-analysis and comprised 3001 patients from 4 RCTs and 5 non-randomized. The majority of patients (57.1%) underwent open retromuscular repair. HW mesh was significantly associated with increased in foreign body sensation (OR 3.71; 95% CI 1.40–9.84;
p
= 0.008), but there was no difference in other outcomes. In RCTs analysis, there was no difference between meshes. In open retromuscular repairs, HW mesh was associated with more seromas (OR 1.48; 95% CI 1.01–2.17;
p
= 0.05).
Conclusion
Our study found that HW mesh was associated with more foreign body sensation. Also, open retromuscular repairs analysis showed that HW was associated with more seromas. Further randomized studies are needed to understand better the role of HW mesh in ventral hernia repair. |
---|---|