A triple-aptamer tetrahedral DNA nanostructures based carbon-nanotube-array transistor biosensor for rapid virus detection

Outbreaks of infectious viruses cause enormous challenges to global public health. Recently, the coronavirus disease 2019 (COVID-19) induced by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has severely threatened human health and resulted in the global pandemic. A strategy to det...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2024-01, Vol.266 (Pt 1), p.124973-124973, Article 124973
Hauptverfasser: Ma, Shenhui, Ren, Qinqi, Jiang, Leying, Liu, Zhihong, Zhu, Yang, Zhu, Jiahao, Zhang, Yaping, Zhang, Min
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Outbreaks of infectious viruses cause enormous challenges to global public health. Recently, the coronavirus disease 2019 (COVID-19) induced by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has severely threatened human health and resulted in the global pandemic. A strategy to detect SARS-CoV-2 with both fast sensing speed and high accuracy is urgently required. Here, rapid detection of SARS-CoV-2 antigen using carbon-nanotube-array-based thin-film transistor (CNT-array-based TFT) biosensors merged with tetrahedral DNA nanostructures (TDNs) and triple aptamers is demonstrated for the first time. Compared with CNT-network-based TFT biosensors and metal-electrode-based CNT-TFT biosensors, the response of CNT-array-based TFT biosensors can be enhanced up to 102% for SARS-CoV-2 receptor-binding domain (RBD) detection, which is supported by its sensing mechanism. By combining TDNs with triple aptamers, the biosensor has realized the wildtype SARS-CoV-2 RBD detection in a broad detection range spanning eight orders of magnitude with a low limit of detection (LOD) of 10 aM (6 copies/μL) owing to the improved protein capture efficiency. Moreover, the triple-aptamer biosensor platform has achieved the detection of SARS-CoV-2 Omicron RBD in a low LOD of 6 aM (3.6 copies/μL). Additionally, the CNT-array-based TFT biosensors have exhibited excellent specificity, enabling identification among SARS-CoV-2 antigen, SARS-CoV antigen and MERS-CoV antigen. The platform of CNT-array-based TFT biosensors combined with TDNs and triple aptamers provides a high-performance and rapid approach for SARS-CoV-2 detection, and its versatility by altering specific aptamers enables the possibility for rapid virus detection. [Display omitted] •A CNT-array-based thin-film transistor for SARS-CoV-2 detection is reported.•The biosensor response can improve to 102% using triple-aptamer DNA tetrahedrons.•The detection of wildtype SARS-CoV-2 RBD was achieved in a low LOD of 10 aM.•The platform realized the SARS-CoV-2 Omicron RBD detection with LOD of 6 aM.•The distinction among antigens of SARS-CoV-2, SARS-CoV and MERS-CoV was achieved.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2023.124973