Partitions and trigger supervision in Aleph
The Aleph data acquisition system is controlled by a set of protocols that are implemented both in software and on dedicated hardware. The authors describe these protocols, how they fulfil the design requirements, and the specific hardware supporting them. In particular, they give an overview of the...
Gespeichert in:
Veröffentlicht in: | IEEE (Institute of Electrical and Electronics Engineers) Transactions on Nuclear Science; (USA) 1989-10, Vol.36 (5), p.1464-1468 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The Aleph data acquisition system is controlled by a set of protocols that are implemented both in software and on dedicated hardware. The authors describe these protocols, how they fulfil the design requirements, and the specific hardware supporting them. In particular, they give an overview of the Aleph readout and describe the readout controller, the transmission of trigger signals, the readout procedure, and the cable protocol. The authors discuss the requirements for partitioning Aleph, the topology constraints, and resource management. They detail the trigger supervisor, its functions, and the handling of errors.< > |
---|---|