Electrochemical sensor for sensitive detection of bisphenol A based on molecularly imprinted TiO2 with oxygen vacancy

Bisphenol A (BPA) is an endocrine disrupting chemical and broadly used in plastics. The leakage of BPA in food and water cycles poses a significant risk to the environment and human health. Thus, monitoring the concentration of BPA to avoid its potential risk is highly important. In this work, a sim...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 2023-10, Vol.237, p.115520-115520, Article 115520
Hauptverfasser: Liu, Yu-Huan, Liu, Chang, Wang, Xin-Hui, Li, Tong, Zhang, Xing
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Bisphenol A (BPA) is an endocrine disrupting chemical and broadly used in plastics. The leakage of BPA in food and water cycles poses a significant risk to the environment and human health. Thus, monitoring the concentration of BPA to avoid its potential risk is highly important. In this work, a simple and efficient oxygen deficient molecularly imprinted TiO2 electrochemical sensor was proposed for the detection of BPA. The introduction both oxygen vacancies and molecular imprinting evidently enhanced the electrochemical oxidation signal of BPA. The sensor had a good linear response ranging from 0.01 μM to 20 μM with a limit of detection of 3.6 nM. Additionally, the sensor showed remarkable stability, reproducibility and interference resistant ability. It also exhibits excellent recovery during the detection of real water. These findings suggested that the sensor has the potential to be developed as a simple, efficient and low-cost monitoring system for the monitoring of BPA in water.
ISSN:0956-5663
1873-4235
DOI:10.1016/j.bios.2023.115520