Pressure drop model of DPF considering ash factor at different capture stages

In this paper, a pressure drop model of diesel particulate filter (DPF) is established on diesel bench loading tests and simulation studies. A proposed DPF soot loading prediction model takes into account the different factors and calculation methods of pressure drop formation in different capture s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy (Oxford) 2023-11, Vol.283, p.128439, Article 128439
Hauptverfasser: Tan, Piqiang, Cui, Bokuan, Duan, Lishuang, Yin, Yifan, Lou, Diming, Hu, Zhiyuan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, a pressure drop model of diesel particulate filter (DPF) is established on diesel bench loading tests and simulation studies. A proposed DPF soot loading prediction model takes into account the different factors and calculation methods of pressure drop formation in different capture stages, including deep bed capture stage, transitional capture stage and soot cake capture stage. Further, a pressure drop model of DPF is improved, and the model for different filter wall permeability in different capture stages is discussed. The calculated results of the model are verified with the experimental results. Finally, the influence of ash factor on the modification of DPF pressure drop model was investigated. The results show that, when the ash layer is 0.05 mm–0.15 mm in the deep bed capture stage, the modified values of filtration wall permeability are 8.2%–43.8% of the original values. In the transitional capture stage, the ash layer with thickness of 0.01 mm–0.05 mm needs to modify 0.75 g/L∼1.5 g/L soot loading. The DPF pressure drop and the particle soot cake layer thickness increase linearly with time in the soot cake capture stage. When the ash layer changes in the range of 0.05 mm–0.15 mm, the soot loading is modified to 13.4%–36.8% of the original value. When the axial scale of the ash plug is 1/5,1/4 and 1/3 of the DPF length, the soot loading is corrected to 33.3%, 37.3% and 45.1%. •The pressure drop model comprehensively considers the effects of different capture stages.•A calculation tool for quickly calculating the effect of ash was designed.•This calculation tool is able to correct soot load calculations at different capture stages.
ISSN:0360-5442
DOI:10.1016/j.energy.2023.128439