Temperature Distribution Measurement in EDM Arc Plasma Using Spectroscopy

This paper describes the measurement of temperature distribution in EDM arc plasma using spectroscopic analysis. The temperature distribution measurement was achieved by using a lens system to magnify the image of the plasma and a mask to limit the plasma region to be observed. The fluxes of two dif...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JSME International Journal Series C Mechanical Systems, Machine Elements and Manufacturing Machine Elements and Manufacturing, 2004, Vol.47(1), pp.384-390
Hauptverfasser: NATSU, Wataru, OJIMA, Satoyuki, KOBAYASHI, Teruki, KUNIEDA, Masanori
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper describes the measurement of temperature distribution in EDM arc plasma using spectroscopic analysis. The temperature distribution measurement was achieved by using a lens system to magnify the image of the plasma and a mask to limit the plasma region to be observed. The fluxes of two different wavelength spectra radiated from the arc plasma were measured simultaneously with optical fibers and photomultipliers, after which the temperature distribution was computed from the radiant fluxes using the line pair method and Ablel's inversion. Also, the influences of machining conditions, such as electrode shape, gap distance and discharge current, on the temperature distribution were investigated.
ISSN:1344-7653
1347-538X
DOI:10.1299/jsmec.47.384