An eco-friendly sample preparation procedure based on air-assisted liquid-liquid microextraction for the rapid determination of phthalate metabolites in urine samples by liquid chromatography-tandem mass spectrometry

Urinary phthalate metabolite (mPAEs) analysis is a reliable tool for assessing human exposure to phthalates. With growing interest in urinary biomonitoring of these metabolites, there is a need for fast and sensitive analytical methods. Therefore, a simple, rapid procedure for simultaneous determina...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2024-01, Vol.266 (Pt 1), p.124974-124974, Article 124974
Hauptverfasser: Alves Rocha, Bruno, Gallimberti, Matheus, Paulo Bianchi Ximenez, João, Giovana Basso, Carla, Joel Martino-Andrade, Anderson, Martin Koch, Holger, Augusto Calixto, Leandro, Barbosa, Fernando
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Urinary phthalate metabolite (mPAEs) analysis is a reliable tool for assessing human exposure to phthalates. With growing interest in urinary biomonitoring of these metabolites, there is a need for fast and sensitive analytical methods. Therefore, a simple, rapid procedure for simultaneous determination of fifteen phthalate metabolites in human urine samples by liquid chromatography-tandem mass spectrometry was developed. The novelty of the present procedure is based on the use of diethyl carbonate as a green biobased extraction solvent and air-assisted liquid-liquid microextraction (AALLME) as a sample preparation step. A Plackett-Burman design was used for screening the factors that influence the AALLME extraction efficiency of mPAEs. The effective factors were then optimized by response surface methodology using a central composite rotatable design. Under the optimized conditions, good linearity can be achieved in a concentration range of 1.0–20.0 ng mL-1 with correlation coefficients higher than 0.99. The repeatability and reproducibility precision were in the range of 2–12% and 1–10% respectively. Recoveries ranging from 90% to 110%. This, and the low limits of detection, ranging from 0.01 to 0.05 ng mL-1, make the proposed procedure sensitive and suitable for human biomonitoring of phthalate exposures. For proof-of-principle, the new method was used to measure the urinary concentrations of mPAEs in 20 urine samples from Brazilian women. The high frequency of detections and in part high concentrations of mPAEs indicate to widespread exposure to several phthalates among Brazilian women. [Display omitted] •A simple, rapid, sensitive and accurate method for 15 phthalate metabolites determination in human urine is proposed.•The proposed method is eco-friendly, as a green bio-based extraction solvent was used.•The method is based on air-assisted liquid-liquid microextraction and liquid chromatography coupled to mass spectrometry.•The proposed method was successfully applied for the analysis of Brazilian women urine samples.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2023.124974