Measured-loss analysis of superconducting power transmission cable
In the former work (see T.Hoshino et al., ibid., vol.9, no.2, pp.1277-80, 1999), the eddy current loss in the former due to pitch difference between current conductor and shield conductor was studied. The calculated value was negligible small which does not explain the measured value. The eddy curre...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2000-03, Vol.10 (1), p.1223-1226 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In the former work (see T.Hoshino et al., ibid., vol.9, no.2, pp.1277-80, 1999), the eddy current loss in the former due to pitch difference between current conductor and shield conductor was studied. The calculated value was negligible small which does not explain the measured value. The eddy current loss due to radial component of the magnetic field become comparable with the measured value. In this paper, the reason of the increased loss is revealed. The disturbance of the conductor pitch yields different strength of the axial magnetic field. The difference of the axial flux toward the radial direction as the radial component of the flux. The flux causes eddy current loss in the copper for stabilizer. It is well match with the measured value. |
---|---|
ISSN: | 1051-8223 1558-2515 |
DOI: | 10.1109/77.828455 |