Determination of Cl and S in crude oil by ICP-OES after sample digestion by microwave-induced combustion in disposable vessels
A simple, fast and promising sample preparation method based on microwave-induced combustion in disposable vessels (MIC-DV) was developed for Cl and S determination in crude oil by inductively coupled plasma optical emission spectrometry (ICP-OES). The MIC-DV consists of a new approach of convention...
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 2023-09, Vol.1273, p.341536-341536, Article 341536 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A simple, fast and promising sample preparation method based on microwave-induced combustion in disposable vessels (MIC-DV) was developed for Cl and S determination in crude oil by inductively coupled plasma optical emission spectrometry (ICP-OES). The MIC-DV consists of a new approach of conventional microwave-induced combustion (MIC). For the combustion, crude oil was pipetted on a disk of filter paper and placed on a quartz holder, followed by the addition of igniter solution (40 μL of 10 mol L−1 NH4NO3). The quartz holder was inserted into a commercial 50 mL disposable polypropylene vessel containing the absorbing solution, which was then inserted in an aluminium rotor. The combustion occurs under atmospheric pressure in a domestic microwave oven not compromising the operator's safety. The following parameters of combustion were evaluated: type, concentration and volume of absorbing solution, sample mass and the possibility of performing consecutive combustion cycles. Using MIC-DV, up to 10 mg of crude oil were efficiently digested, using 2.5 mL of ultrapure H2O as absorbing solution. Moreover, up to 5 consecutive combustion cycles were possible without analyte losses, reaching a total sample mass of 50 mg. The MIC-DV method was validated according to Eurachem Guide recommendations. Results obtained for Cl and S by MIC-DV were in agreement with those obtained using conventional MIC, as well as those obtained for S in a certified reference material of crude oil (NIST 2721). Analyte spike recovery experiments were performed and recoveries at three concentration levels ranged from 99 to 101% for Cl and from 95 to 97% for S, indicating a good accuracy. The limit of quantification achieved by ICP-OES after MIC-DV were 73 and 50 μg g−1 for Cl and S respectively, applying 5 consecutive combustion cycles.
[Display omitted]
•MIC-DV was considered an efficient and promising method for crude oil digestion.•Up to 5 consecutive combustion cycles were possible without analyte losses.•MIC-DV presents a short time for digestion, simplicity and is easy to use.•The combination of MIC-DV and ICP-OES provided the Cl and S determination in different crude oils.•Time-consuming methods and large amounts of reagents were avoided. |
---|---|
ISSN: | 0003-2670 1873-4324 |
DOI: | 10.1016/j.aca.2023.341536 |