A MM-wave radiometer with planar Nb/a-Si/Nb Josephson junction
A report is presented on an investigation of the electrical and detection properties of thin-film step-edge submicron Nb/a-Si/Nb Josephson junctions for use as a detector in radioastronomical radiometers. These junctions are stable, thermally recyclable junctions with nonhysteretic I-V characteristi...
Gespeichert in:
Veröffentlicht in: | IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States) 1991-03, Vol.27 (2), p.2468-2471 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A report is presented on an investigation of the electrical and detection properties of thin-film step-edge submicron Nb/a-Si/Nb Josephson junctions for use as a detector in radioastronomical radiometers. These junctions are stable, thermally recyclable junctions with nonhysteretic I-V characteristics, R/sub n/=(20-200) Omega and j/sub c/ approximately 10/sup 5/ A/cm. A wideband modulation radiometer for the 4-mm-wavelength range with a Nb/a-Si/Nb Josephson junction has been developed. The best fluctuation sensitivity has been achieved at 0.007 K for a 1-s. integration time. |
---|---|
ISSN: | 0018-9464 1941-0069 |
DOI: | 10.1109/20.133719 |