Magnetic changes in GMR heads caused by electrostatic discharge

The effects of current transients on the magnetic response of GMR sensors is studied. It is shown that GMR sensors with an FeMn exchange layer exhibit large magnetic changes after a single ESD current transient. The energy which results in magnetic failure is only 0.9 nJ, which is much less than the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on magnetics 1998-07, Vol.34 (4), p.1519-1521
Hauptverfasser: Wallash, A., Kim, Y.K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The effects of current transients on the magnetic response of GMR sensors is studied. It is shown that GMR sensors with an FeMn exchange layer exhibit large magnetic changes after a single ESD current transient. The energy which results in magnetic failure is only 0.9 nJ, which is much less than the 6 nJ which causes physical melting damage to the GMR sensor. These serious magnetic changes are explained in terms of resetting of the FeMn exchange layer direction due to the elevated temperature and internal magnetic field during the current transient. It is concluded that ESD stress testing of GMR sensors has revealed a new and important magnetic failure mechanism in GMR sensors.
ISSN:0018-9464
1941-0069
DOI:10.1109/20.706602