The impact of using the internal mammary artery as a recipient vessel on medial mastectomy skin flap perfusion in autologous breast reconstruction: An observational study using indocyanine green

The internal mammary artery (IMA) is the preferred recipient vessel for microvascular anastomosis in immediate autologous breast reconstruction following skin-sparing mastectomy (SSM). Although the IMA accounts for approximately 60% of the blood supply to the breast, the exact contribution to the ma...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of plastic, reconstructive & aesthetic surgery reconstructive & aesthetic surgery, 2023-09, Vol.84, p.350-356
Hauptverfasser: Pruimboom, T., Tuinder, S.M.H., Qiu, S.S., Keuter, X.H.A., van der Hulst, R.R.W.J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The internal mammary artery (IMA) is the preferred recipient vessel for microvascular anastomosis in immediate autologous breast reconstruction following skin-sparing mastectomy (SSM). Although the IMA accounts for approximately 60% of the blood supply to the breast, the exact contribution to the mastectomy skin flap perfusion is unclear. The aim of this observational study was to investigate the impact of using the IMA as a recipient vessel on medial mastectomy skin flap perfusion assessed with indocyanine green angiography (ICGA). This observational study included ten consecutive women who underwent immediate autologous breast reconstructions following SSM. Two intraoperative indocyanine green (ICG) assessments were performed to assess tissue perfusion of the upper and lower part of the medial mastectomy skin flap: the first following the SSM and the second after clamping the IMA. During a 120-second angiography, three additional images were made after 60, 90, and 120 s. The ICG inflow time and mean, minimum, and maximum fluorescence intensities (FIs) were obtained. Four unilateral and six bilateral autologous breast reconstructions were included. There was no difference in tissue perfusion when comparing the inflow time (24.1 s vs. 23.0 s, P = 0.348), the mean FI (131.4 vs. 124.0, P = 0.126), minimum FI (28.6 vs. 33.4, P = 0.086), and maximum FI (253.1 vs. 247.6, P = 0.166) before and after clamping the IMA. According to this study, the use of the IMA as a recipient vessel does not reduce medial mastectomy skin flap perfusion in patients undergoing immediate autologous breast reconstructions following SSM.
ISSN:1748-6815
1878-0539
DOI:10.1016/j.bjps.2023.06.016