Coronary Stent Evaluation by CTA: Image Quality Comparison Between Super-Resolution Deep-Learning Reconstruction and Other Reconstruction Algorithms

A super-resolution deep-learning based reconstruction (SR-DLR) algorithm may provide better image sharpness than earlier reconstruction algorithms and thereby improve coronary stent assessment on coronary CTA. To compare SR-DLR and other reconstruction algorithms in terms of image quality measures r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of roentgenology (1976) 2023-11, Vol.221 (5), p.599-610
Hauptverfasser: Nagayama, Yasunori, Emoto, Takafumi, Hayashi, Hidetaka, Kidoh, Masafumi, Oda, Seitaro, Nakaura, Takeshi, Sakabe, Daisuke, Funama, Yoshinori, Tabata, Noriaki, Ishii, Masanobu, Yamanaga, Kenshi, Fujisue, Koichiro, Takashio, Seiji, Yamamoto, Eiichiro, Tsujita, Kenichi, Hirai, Toshinori
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A super-resolution deep-learning based reconstruction (SR-DLR) algorithm may provide better image sharpness than earlier reconstruction algorithms and thereby improve coronary stent assessment on coronary CTA. To compare SR-DLR and other reconstruction algorithms in terms of image quality measures related to coronary stent evaluation in patients undergoing coronary CTA. This retrospective study included patients with at least one coronary artery stent who underwent coronary CTA between January 2020 and December 2020. Examinations were performed using a 320-row normal-resolution scanner and reconstructed with hybrid iterative reconstruction (HIR), model-based iterative reconstruction (MBIR), normal-resolution deep-learning reconstruction (NR-DLR), and SR-DLR algorithms. Quantitative image quality measures were determined. Two radiologists independently reviewed images to rank the four reconstructions (1=worst reconstruction, 4=best reconstruction) for qualitative measures, and to score diagnostic confidence (5-point scale; score≥3 indicating an assessable stent). Assessability rate was calculated for stents with diameter ≤3.0 mm. The sample included 24 patients (18 men, 6 women; mean age, 72.8±9.8 years), with 51 stents. SR-DLR, in comparison with the other reconstructions, yielded lower stent-related blooming artifacts (median, 40.3 vs 53.4-58.2), stent-induced attenuation increase ratio (0.17 vs 0.27-0.31), and quantitative image noise (18.1 vs 20.9-30.4 HU), and higher in-stent lumen diameter (2.41 vs. 1.74-1.94 mm), stent strut sharpness (327 vs 147-210 ΔHU/mm), and CNR (30.0 vs 16.0-25.6), (all p
ISSN:0361-803X
1546-3141
DOI:10.2214/AJR.23.29506