Gain reduction measurements in transient stimulated Raman scattering
Threshold energy measurements of transient rotational stimulated Raman scattering are compared to Raman conversion calculations from semiclassical theories using a simple concept of a gain reduction factor which expresses the reduction of the gain from its steady-state value due to transient scatter...
Gespeichert in:
Veröffentlicht in: | IEEE journal of quantum electronics 1995-02, Vol.31 (2), p.358-364 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Threshold energy measurements of transient rotational stimulated Raman scattering are compared to Raman conversion calculations from semiclassical theories using a simple concept of a gain reduction factor which expresses the reduction of the gain from its steady-state value due to transient scattering. Excellent agreement was found with theoretically derived gain reduction in the transient and highly transient case.< > |
---|---|
ISSN: | 0018-9197 1558-1713 |
DOI: | 10.1109/3.348067 |