Outcomes of Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) Procedure for the Treatment of Extensive Aortoiliac Occlusive Disease Using the BeGraft Balloon-Expandable Covered Stent: A Multicenter Observational Study
Purpose: The covered endovascular reconstruction of the aortic bifurcation (CERAB) technique offers an alternative for Trans-Atlantic Inter-Society Consensus (TASC) C/D lesions involving the aortic bifurcation. The study aims to evaluate the outcomes of the CERAB technique for extensive aortoiliac o...
Gespeichert in:
Veröffentlicht in: | Journal of endovascular therapy 2023-06, p.15266028231180350-15266028231180350 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose:
The covered endovascular reconstruction of the aortic bifurcation (CERAB) technique offers an alternative for Trans-Atlantic Inter-Society Consensus (TASC) C/D lesions involving the aortic bifurcation. The study aims to evaluate the outcomes of the CERAB technique for extensive aortoiliac occlusive disease (AIOD) using the BeGraft balloon-expandable covered stent (BECS).
Materials and Methods:
This is a physician-initiated, multicenter, retrospective, observational study. Between June 2017 and June 2021, all consecutive patients who underwent the CERAB procedure using the BeGraft stent (Bentley InnoMed, Hechingen, Germany) in 3 clinics were enrolled. Patients’ demographics, lesion characteristics, and procedural results were collected and retrospectively analyzed. Follow-up was done at 1, 6, and 12 months and then annually with clinical examination, ankle-brachial index (ABI), and duplex ultrasound. The primary endpoint was the patency at 12 months. Secondary endpoints included procedural-related complications, secondary patency, freedom from target lesion revascularization (TLR), and clinical improvement.
Results:
In all, 120 patients (64 men) with a median age of 65 years (range: 34–84 years) were analyzed. Most patients had extensive AIOD classified as TASC II C (n=32; 26.7%) or TASC II D (n=81; 67.5%). The median duration of the procedure was 120 minutes (interquartile range [IQR]: 80–180 minutes). All 454 BeGraft stents (137 aortic and 317 peripheral) were successfully delivered and deployed. The overall procedural complication rate was 14 (11.7%). The median hospital length of stay was 5 days (IQR: 3–6 days). All patients improved clinically, and the ABI increased significantly (p |
---|---|
ISSN: | 1526-6028 1545-1550 |
DOI: | 10.1177/15266028231180350 |