Remotely operated robotic microscopy for rapid diagnosis of bronchoscopic cytology specimens
Background Obtaining a diagnosis and treating pulmonary malignancies during the same anesthesia requires either an on‐site pathologist or a system for remotely evaluating microscopic images. Cytology specimens are challenging to remotely assess given the need to navigate through dispersed and three‐...
Gespeichert in:
Veröffentlicht in: | Diagnostic cytopathology 2023-09, Vol.51 (9), p.554-562 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Obtaining a diagnosis and treating pulmonary malignancies during the same anesthesia requires either an on‐site pathologist or a system for remotely evaluating microscopic images. Cytology specimens are challenging to remotely assess given the need to navigate through dispersed and three‐dimensional cell clusters. Remote navigation is possible using robotic telepathology, but data are limited on the ease of use of current systems, particularly for pulmonary cytology.
Methods
Air dried modified Wright‐Giemsa stained slides from 26 touch preparations of transbronchial biopsies and 27 smears of endobronchial ultrasound guided fine needle aspirations were scored for ease of adequacy assessment and ease of diagnosis on robotic (rmtConnect Microscope) and non‐robotic telecytology platforms. Diagnostic classifications were compared between glass slides and the robotic and non‐robotic telecytology assessments.
Results
Compared to non‐robotic telecytology, robotic telecytology had a greater ease of adequacy assessment and non‐inferior ease of diagnosis. The median time to diagnosis using robotic telecytology was 85 s (range 28–190 s). Diagnostic categories were concordant for 76% of cases in robotic versus non‐robotic telecytology and 78% of cases in robotic telecytology versus glass slide diagnosis. Weighted Cohen's kappa scores for agreement in these comparisons were 0.84 and 0.72, respectively.
Conclusions
Use of a remote‐controlled robotic microscope improved the ease of adequacy assessment compared to non‐robotic telecytology and enabled strongly concordant diagnoses to be expediently rendered. This study provides evidence that modern robotic telecytology is a feasible and user‐friendly method of remotely and potentially intraoperatively rendering adequacy assessments and diagnoses on bronchoscopic cytology specimens. |
---|---|
ISSN: | 8755-1039 1097-0339 |
DOI: | 10.1002/dc.25177 |