High Temperature Microhardness of Single Crystal Mullite
The microhardness (H) of single crystal, orthorhombic mullite was measured on (010) and (001) faces from room temperature up to 1400°C. The microhardness versus temperature curves display sigmoidal shapes. The mean microhardness at room temperature is ∼16 Gpa and it decreases with temperature to H i...
Gespeichert in:
Veröffentlicht in: | Journal of the American Ceramic Society 2004-05, Vol.87 (5), p.970-972 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The microhardness (H) of single crystal, orthorhombic mullite was measured on (010) and (001) faces from room temperature up to 1400°C. The microhardness versus temperature curves display sigmoidal shapes. The mean microhardness at room temperature is ∼16 Gpa and it decreases with temperature to H is ∼ 13 GPa at 300°C. At >300°C, the microhardness is only slightly reduced with temperature to H is ∼10 GPa at 1000°C. Above this temperature limit, it markedly decreases again, to a mean value of ≈6 GPa at 1400°C. Up to ∼1000°C the (010) and (001) microhardnesses are very similar. Above ∼1000°C, however, the hardness gradually becomes anisotropic, with H(010) being twice as high as H(001) at 1400°C (H(010)∼ 8 GPa, H(001)∼ 4 GPa). |
---|---|
ISSN: | 0002-7820 1551-2916 |
DOI: | 10.1111/j.1551-2916.2004.00970.x |