BCR intercomparison of AC-DC current transfer standards

The established national standards for ac-dc current transfer and the respective measurement set-ups of Denmark, France, Germany, Italy, Sweden, and The Netherlands were intercompared in the current range from 10 mA to 20 A and in the frequency range from 10 Hz to 100 kHz. An agreement within 10 ppm...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on instrumentation and measurement 1995-04, Vol.44 (2), p.403-406
Hauptverfasser: Klonz, M., Bergeest, R., Caizergues, A., Fraisse, D., Winther, C.A.D., Pogliano, U., Cabiati, F., Bosco, G.C., Zago, G., Dessens, J.T., de Vreede, J.P.M., Rydler, K.-E., Nilsson, H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The established national standards for ac-dc current transfer and the respective measurement set-ups of Denmark, France, Germany, Italy, Sweden, and The Netherlands were intercompared in the current range from 10 mA to 20 A and in the frequency range from 10 Hz to 100 kHz. An agreement within 10 ppm to 30 ppm was obtained up to 100 mA, degrading to 100 ppm at 1 A (100 kHz) and 70 ppm at 10 A (20 kHz) and 20 A (5 kHz).< >
ISSN:0018-9456
1557-9662
DOI:10.1109/19.377864