Effect of computed tomography angiography prior to bronchial embolization on radiation dose and recurrent hemoptysis

To investigate whether pre-procedure Computed Tomography Angiography (CTA) improves radiation exposure, procedure complexity, and symptom recurrence after bronchial embolization for massive hemoptysis. A single-center retrospective review of bronchial artery embolization (BAE) for massive hemoptysis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical imaging 2023-08, Vol.100, p.48-53
Hauptverfasser: Herrera, Daniel Giraldo, Ostad, Bahrom J., Wilkins, Luke R., Sheeran, Daniel P., Park, Auh Whan, Goode, Allen R., Patrie, James T., Angle, John F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To investigate whether pre-procedure Computed Tomography Angiography (CTA) improves radiation exposure, procedure complexity, and symptom recurrence after bronchial embolization for massive hemoptysis. A single-center retrospective review of bronchial artery embolization (BAE) for massive hemoptysis was performed for procedures between 2008 and 2019. Multi-variate analysis was performed to determine the significance of pre-procedure CTA and etiology of hemoptysis on patient radiation exposure (reference point air kerma, RPAK) and rate of recurrent hemoptysis. There were 61 patients (mean age 52.5 years; SD = 19.2 years, and 57.3% male) and CTA was obtained for 42.6% (26/61). Number of vessels selected was a mean of 7.2 (SD = 3.4) in those without CTA and 7.4 (SD = 3.4) in those with CTA (p = 0.923). Mean procedure duration was 1.8 h (SD = 1.6 h) in those without CTA and 1.3 h (SD = 1.0 h) in those with CTA (p = 0.466). Mean fluoroscopy time and RPAK per procedure were 34.9 min (SD = 21.5 min) and 1091.7 mGy (SD = 1316.6 mGy) for those without a CTA and 30.7 min (SD = 30.7 min) and 771.5 mGy (SD = 590.0 mGy) for those with a CTA (p = 0.523, and p = 0.879, respectively). Mean total iodine given was 49.2 g (SD = 31.9 g) for those without a CTA and 70.6 g (SD = 24.9 g) for those with a CTA (p = 0.001). Ongoing hemoptysis at last clinical follow up was 13/35 (37.1%) in those without CTA and 9/26 (34.6%) in those with CTA (p = 0.794). Pre-procedure CTA did not improve radiation effective dose and symptom recurrence after BAE and is associated with significant increases in total iodine dose. •Bronchial artery embolization can be performed without pre-procedure cross-sectional imaging.•Computed tomography angiography does not add significant radiation effective dose.•Cases with an otherwise suspected bleeding site should proceed directly to interventional treatment.
ISSN:0899-7071
1873-4499
DOI:10.1016/j.clinimag.2023.04.007