Integrated membrane-free thermal flow sensor for silicon-on-glass microfluidics

Lab-on-a-chip (LOC) forms the basis of new-generation portable analytical systems. LOC allows the manipulation of ultralow flows of liquid reagents and multistep reactions on a microfluidic chip, which requires a robust and precise instrument to control the flow of liquids on a chip. However, commer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lab on a chip 2023-06, Vol.23 (12), p.2789-2797
Hauptverfasser: Ryzhkov, Vitaly V, Echeistov, Vladimir V, Zverev, Aleksandr V, Baklykov, Dmitry A, Konstantinova, Tatyana, Lotkov, Evgeny S, Ryazantcev, Pavel G, Sh. Alibekov, Ruslan, Kuguk, Aleksey K, Aleksandrov, Andrey R, Krasko, Elisey S, Barbasheva, Anastasiya A, Ryzhikov, Ilya A, Rodionov, Ilya A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Lab-on-a-chip (LOC) forms the basis of new-generation portable analytical systems. LOC allows the manipulation of ultralow flows of liquid reagents and multistep reactions on a microfluidic chip, which requires a robust and precise instrument to control the flow of liquids on a chip. However, commercially available flow meters appear to be a standalone option adding a significant dead volume of tubes for connection to the chip. Furthermore, most of them cannot be fabricated within the same technological cycle as microfluidic channels. Here, we report on a membrane-free microfluidic thermal flow sensor (MTFS) that can be integrated into a silicon-glass microfluidic chip with a microchannel topology. We propose a membrane-free design with thin-film thermo-resistive sensitive elements isolated from microfluidic channels and a 4′′ wafer silicon-glass fabrication route. It ensures MTFS compatibility with corrosive liquids, which is critically important for biological applications. MTFS design rules for the best sensitivity and measurement range are proposed. A method for automated thermo-resistive sensitive element calibration is described. The device parameters are experimentally tested for hundreds of hours with a reference Coriolis flow sensor demonstrating a relative flow error of less than 5% within the range of 2-30 μL min −1 along with a sub-second time response. Design, electronics, fabrication technology, and characterization method of an on-chip corrosion-resistant microfluidic thermal flow sensor for silicon lab-on-a-chip and POC devices.
ISSN:1473-0197