DC Flow Suppression In A Single-Stage G-M Type Pulse Tube Cooler

An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallel-placed needle valves with an opp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Transactions of Nanjing University of Aeronautics & Astronautics 2004-12, Vol.21 (4), p.277-280
Hauptverfasser: Jiang, Yan-Long, Chen, Guo-Bang, Thummes, Guenter
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallel-placed needle valves with an opposite flow direction called as double-valved configuration, instead of conventional single-valved configuration as the double-inlet is used to reduce the DC flow. With the double-valved configuration, the minimum temperatures of 18.4 K and 14.7 K, and the cooling powers of 11.5 W and 29.5 W are also obtained by RW2 and CP4000, respectively.