Some experimental studies on time-of-flight radiography using a pulsed neutron source

We are developing a fiber type two-dimentional (2-D) position-sensitive detector having a spatial resolution less than 0.5 mm in order to use it in the time-of-flight (TOF) measurements. The detector performance was examined, and some experiments on the TOF radiography were performed using this dete...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2005-02, Vol.52 (1), p.371-374
Hauptverfasser: Kiyanagi, Y., Sakamoto, N., Iwasa, H., Kamiyama, T., Hiraga, F., Sato, S., Sagehashi, H., Ino, T., Furusaka, M., Suzuki, J., Gorin, A., Manuilov, I., Ryazantsev, A., Kuroda, K., Sakai, K., Tokanai, F., Miyasaka, H., Adachi, T., Oku, T., Ikeda, K., Suzuki, S., Morimoto, K., Shimizu, H.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We are developing a fiber type two-dimentional (2-D) position-sensitive detector having a spatial resolution less than 0.5 mm in order to use it in the time-of-flight (TOF) measurements. The detector performance was examined, and some experiments on the TOF radiography were performed using this detector. The results indicated that the detector could be applied successfully to the TOF measurement and that the TOF radiography was very useful since it gave more informative data than those obtained by the conventional radiography using a broad energy band.
ISSN:0018-9499
1558-1578
DOI:10.1109/TNS.2005.844299