Patient-specific instrumentation for medial opening wedge high tibial osteotomies in the management of medial compartment osteoarthritis yields high accuracy and low complication rates: A systematic review

There has been growing interest in the use of patient-specific instrumentation (PSI) to maximise accuracy and minimise the risk of major complications for medial opening-wedge high tibial osteotomies (MOW-HTOs). Numerous studies have reported the efficacy and safety of implementing this technology i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of ISAKOS 2023-06, Vol.8 (3), p.163-176
Hauptverfasser: Dasari, Suhas P., Hevesi, Mario, Mameri, Enzo, Ferrer-Rivero, Robert, Fortier, Luc M., Jackson, Garrett R., Warrier, Alec A., Maheshwer, Bhargavi, Jawanda, Harkirat, Khan, Zeeshan A., Kerzner, Benjamin, Browning, Robert B., Gursoy, Safa, Chahla, Jorge
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:There has been growing interest in the use of patient-specific instrumentation (PSI) to maximise accuracy and minimise the risk of major complications for medial opening-wedge high tibial osteotomies (MOW-HTOs). Numerous studies have reported the efficacy and safety of implementing this technology into clinical practice, yet no systematic review summarising the clinical literature on PSI for MOW-HTOs has been performed to date. The aim of this investigation was to perform a systematic review summarising the evidence surrounding the use of PSI for MOW-HTOs in the management of medial compartment osteoarthritis. PubMed, Scopus, and the Cochrane Library were queried in October 2021 for studies that used PSI for MOW-HTOs when managing medial compartment knee osteoarthritis. Primary outcomes included accuracy in coronal plane correction (mechanical medial proximal tibial angle), sagittal plane correction (posterior tibial slope), and mechanical axis correction (hip-knee-ankle angle [HKA], mechanical femorotibial angle, and weight-bearing line). Accuracy was defined as error between post-operative measurements relative to the planned pre-operative correction. A secondary outcome was the incidence of major complications. This review included eight different techniques among the 14 included studies. There was a weighted mean error of 0.5° (range: 0.1°–1.3°) for the mechanical medial proximal tibial angle, 0.6° (range: 0.3°–2.7°) for the posterior tibial slope, and 0.8° (range: 0.1°–1.0°) for the hip-knee-ankle angle. Four studies compared the correctional error of the mechanical axis between conventional techniques and PSI techniques. The comparative difference between the two techniques favoured the use of PSI for MOW-HTOs (standardised mean difference ​= ​0.52; 95% confidence interval, 0.16 to 0.87; p ​= ​0.004). Among the 14 studies evaluated, four studies explicitly reported no major complications, while five studies reported a non-zero incidence of major complications. Among these nine studies, the weighted mean major complication rate was 7.1% (range: 0.0–13.0%). The findings of this present systematic review suggest that the use of PSI for MOW-HTOs leads to high accuracy relative to the planned corrections in the coronal plane, sagittal plane, and mechanical axis. Furthermore, these findings would suggest there is a low risk of major complications when implementing PSI for MOW-HTOs. Systematic review; IV.
ISSN:2059-7754
2059-7762
DOI:10.1016/j.jisako.2023.02.001