Generation of Q-bead against bone Gla protein with simplified preparation steps
Quenchbody (Q-body)-based immunoassays enable the detection of antigen within a few minutes with high sensitivity and specificity, thereby revealing their applicability as biosensors for quantifying several biomolecules of interest; however, while producing a Q-body, it is necessary to eliminate the...
Gespeichert in:
Veröffentlicht in: | Journal of immunological methods 2023-05, Vol.516, p.113471-113471, Article 113471 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Quenchbody (Q-body)-based immunoassays enable the detection of antigen within a few minutes with high sensitivity and specificity, thereby revealing their applicability as biosensors for quantifying several biomolecules of interest; however, while producing a Q-body, it is necessary to eliminate the unconjugated dye after labeling to separate the Q-body from the capturing bead and to change the buffer using ultrafiltration, which is time-consuming and leads to yield reduction. In this study, we generated a recombinant single chain variable fragment against bone Gla protein as a model antibody. We labeled the antibody with a dye to generate a Q-body and subsequently added affinity beads to the Q-body mixture. After washing, we directly added antigen without extracting the Q-body from the bead and then measured the fluorescence intensity. As a result, the antigen-dependent fluorescence response was obtained from “Q-bead”, which was almost the same as that of the Q-body generated according to the conventional method. The Q-bead was generated within only 2.5 h, thus requiring an hour and two steps less than those required for the generation of the traditional Q-body. No expensive Flag peptide was required to recover the total antibody from beads. Moreover, the ultra-filtration step was eliminated in this bead-based method, leading to improved convenience and cost- and time-saving attributes. The Q-bead-based assay can be used as a standard protocol for simple and rapid analysis of antibody-based molecular detection.
•Generating “Q-bead” by omitting the step of separating the Q-body from beads.•Immunoassay within only 2.5 h, which is shorter than the Q-body-based method.•Simple and rapid assay for versatile antibody-based detection. |
---|---|
ISSN: | 0022-1759 1872-7905 |
DOI: | 10.1016/j.jim.2023.113471 |