Role of recombinant Histoplasma capsulatum 100‐kilodalton antigen in the diagnosis of histoplasmosis among HIV/AIDS patients: Antigenuria and antibodies detection
Background Diagnosing progressive disseminated histoplasmosis (PDH) is still challenging in many countries where this disease is highly endemic. Definitive diagnosis is established by culture and/or by cytology/histopathology but both procedures have limited sensitivity and cultures are time‐consumi...
Gespeichert in:
Veröffentlicht in: | Mycoses 2023-07, Vol.66 (7), p.609-620 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Diagnosing progressive disseminated histoplasmosis (PDH) is still challenging in many countries where this disease is highly endemic. Definitive diagnosis is established by culture and/or by cytology/histopathology but both procedures have limited sensitivity and cultures are time‐consuming. Antibodies detection by immunodiffusion has a low sensitivity in immunocompromised individuals. Commercially available antigen detection assays have high sensitivity in PDH cases; however, they are expensive and only performed in few laboratories.
Aims
To describe the potential use of a novel ELISA for antibodies testing and a dot blot assay for antigen testing for diagnosing PDH using the recombinant 100 kDa protein of Histoplasma capsulatum (Hcp100) and their polyclonal antibodies as novel reagents, respectively.
Methods
Serum and urine samples from a cohort of patients with HIV/AIDS and proven PDH were studied for the detection of anti‐Hcp100 antibodies by ELISA and Hcp100 antigen by dot blot, respectively. Sensitivity, specificity and cross‐reactions with other diseases were estimated for each assay and compared with those obtained using histoplasmin (HMN) as a reagent for antibodies detection by ELISA and immunodiffusion, and using a commercial antigenuria test.
Results
Antibodies detection by the Hcp100 ELISA demonstrated 78.6% sensitivity and 88.4% specificity, versus 85.7% sensitivity and 81.0% specificity for the HMN ELISA and 26.1% sensitivity and 100% specificity for the immunodiffusion assay. Antigen detection by the Hcp100 dot blot demonstrated 89.3% sensitivity and 97.0% specificity versus 82.1% sensitivity and 90.9% specificity for the commercial test.
Conclusion
The immunoassays described herein based on Hcp100 would be a valuable screening tool for diagnosing PDH. |
---|---|
ISSN: | 0933-7407 1439-0507 |
DOI: | 10.1111/myc.13587 |