Ag/MoO3–Pd-mediated gasochromic reaction: An efficient dual-mode photoelectrochemical and photothermal immunoassay
Herein, we presented a dual-readout gasochromic immunosensing platform for accurate and sensitive detection of carcinoembryonic antigen (CEA) based on Ag-doped/Pd nanoparticles loaded MoO3 nanorods (Ag/MoO3–Pd). Initially, the presence of analyte CEA would prompt the formation of sandwich-type immun...
Gespeichert in:
Veröffentlicht in: | Biosensors & bioelectronics 2023-06, Vol.230, p.115267-115267, Article 115267 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Herein, we presented a dual-readout gasochromic immunosensing platform for accurate and sensitive detection of carcinoembryonic antigen (CEA) based on Ag-doped/Pd nanoparticles loaded MoO3 nanorods (Ag/MoO3–Pd). Initially, the presence of analyte CEA would prompt the formation of sandwich-type immunoreaction, accompanied by the introduction of Pt NPs labeled on detection antibody. Upon the addition of NH3BH3, the product hydrogen (H2) will interact with Ag/MoO3–Pd as a bridge between the sensing interface and the biological assembly platform. Both photocurrent and temperature signals can serve as readouts due to the significantly increased PEC performance and enhanced photothermal conversion capability of H–Ag/MoO3–Pd (the product of Ag/MoO3–Pd react with H2) compared to Ag/MoO3–Pd. In addition, the DFT results show that the band gap of Ag/MoO3–Pd becomes narrower after the reaction with H2, thus improving the utilization of light, which theoretically explains the internal mechanism of gas sensing reaction. Under optimal conditions, the designed immunosensing platform showed good sensitivity for CEA detection with the limit of detection (LOD) of 26 pg mL−1 (photoelectrochemical mode) and 98 pg mL−1 (photothermal mode). This work not only presents the possible reaction mechanism of Ag/MoO3–Pd and H2, but also creatively applicate it in photothermal biosensors that give a new path for devising dual-readout immunosensor.
•A photoelectrochemical and photothermal dual-readout biosensor was constructed for CEA detection.•Gasochromic material used in PEC/photothermal immunoassay.•The dual-readout biosensor showed high accuracy and stability for CEA detection.•Separation of the sensing interface from the biological assembly platform. |
---|---|
ISSN: | 0956-5663 1873-4235 |
DOI: | 10.1016/j.bios.2023.115267 |