Using a continuous electrocardiographic patch with heart rhythm analysis in the subacute stage of aneurysmal subarachnoid hemorrhage: The feasibility verification
Continuous cardiac monitoring on patients with aneurysmal subarachnoid hemorrhage (aSAH) is difficult out of intensive care unit (ICU) in the subacute stage. Therefore, we verified the feasibility of a novel electrocardiography (ECG) patch device to record long-term heart rhythm. The ECG patches wer...
Gespeichert in:
Veröffentlicht in: | Clinical neurology and neurosurgery 2023-05, Vol.228, p.107687-107687, Article 107687 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Continuous cardiac monitoring on patients with aneurysmal subarachnoid hemorrhage (aSAH) is difficult out of intensive care unit (ICU) in the subacute stage. Therefore, we verified the feasibility of a novel electrocardiography (ECG) patch device to record long-term heart rhythm.
The ECG patches were applied on aSAH patients during their stay in general ward. Any types of significant arrythmia were identified, and heart rate variability (HRV) measures were calculated in time and frequency domains. We analyzed the correlation between heart rhythm with Hunt and Hess scale and modified Fisher scale as well as the occurrence of secondary complications.
Twenty-six patients used the devices on median day 6 after aSAH onset, with put on and take down time average as 137 s and 45 s, respectively. Mean record time was 221.7 h, and no adverse event presented within the period. Hunt and Hess II/III subgroup had higher percentage of HRV high frequency band than IV/V subgroup (9.1 % vs 3.5 %, p = 0.043), whereas ultra low frequency band presented more in the later subgroup (50.4 % vs 61.4 %, p = 0.035). The very low frequency percentage significantly decreased (p = 0.025) at an average of 3 days prior to the occurrence of secondary complications compared to the days without complications.
For aSAH patients in general ward during subacute stage, the ECG patch is a safe and feasible tool. The correlation of long-term heart rhythm with prognosis is worthy to be investigated on larger sample size using this device in the future.
•The novel ECG patch is safe and feasible for aSAH patients in the general ward where continuous monitoring is unavailable.•Continuous long-term rhythm recording is important for subtle arrhythmia detection and HRV analysis on aSAH patients.•We demonstrated the potential to identify heart rhythm biomarker associated with prognosis by using a new tool. |
---|---|
ISSN: | 0303-8467 1872-6968 |
DOI: | 10.1016/j.clineuro.2023.107687 |