Performance characteristics of mechanical foam-breakers fitted to a stirred-tank reactor
In a stirred‐tank reactor (STR), a comparison of the performance of mechanical foam‐breakers: a six‐blade turbine (F‐B), a six‐blade vaned disk (V‐D), a two‐blade paddle (T‐P), a conical rotor (C‐R), a fluid‐impact dispersion apparatus (FIDA) and a rotating disk mechanical foam‐breaker (MFRD) was ca...
Gespeichert in:
Veröffentlicht in: | Journal of chemical technology and biotechnology (1986) 2003-01, Vol.78 (1), p.48-55 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In a stirred‐tank reactor (STR), a comparison of the performance of mechanical foam‐breakers: a six‐blade turbine (F‐B), a six‐blade vaned disk (V‐D), a two‐blade paddle (T‐P), a conical rotor (C‐R), a fluid‐impact dispersion apparatus (FIDA) and a rotating disk mechanical foam‐breaker (MFRD) was carried out using defined foaming media. The foam‐breaking ranges (relative to the gas superficial velocity, Ug) of the T‐P, C‐R and FIDA were inferior to that of the F‐B, V‐D and MFRD. The power consumption, Pkc, for foam‐breaking in the MFRD was the lowest among the F‐B, V‐D and MFRD. Operation of the F‐B and V‐D in the STR caused a considerable amount of liquid droplets from the collapsed foam to be entrained with the exhaust air.
© 2002 Society of Chemical Industry |
---|---|
ISSN: | 0268-2575 1097-4660 |
DOI: | 10.1002/jctb.741 |