Magnetic Leakage Field of an Elastically Bent Ferromagnetic Steel Pipe

The tangential component of the leakage field on the surface of an elastically bent long pipe is calculated in the approximation of the uniform internal magnetic field. The tangential component turns out to be more informative than the normal component since, as distinct from the latter, it enables...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Russian journal of nondestructive testing 2003-05, Vol.39 (5), p.381-386
Hauptverfasser: Kuleev, V. G., Lopatin, V. V.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The tangential component of the leakage field on the surface of an elastically bent long pipe is calculated in the approximation of the uniform internal magnetic field. The tangential component turns out to be more informative than the normal component since, as distinct from the latter, it enables us to determine points at which the flexible stresses coincide with the mean value of the internal stresses of the first kind. [Material: St3.]