One-step laser synthesis platinum nanostructured 3D porous graphene: A flexible dual-functional electrochemical biosensor for glucose and pH detection in human perspiration

There has been a recent increase in the demand for wearable sensors for sweat glucose monitoring to facilitate diabetes management in a patient-friendly and non-invasive manner. To address this issue, the key challenge lies in the design of flexible sensors with high conductivity, miniaturized patte...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2023-05, Vol.257, p.124362-124362, Article 124362
Hauptverfasser: Wang, Ying, Guo, Haojie, Yuan, Min, Yu, Jiabing, Wang, Zeping, Chen, Xianping
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:There has been a recent increase in the demand for wearable sensors for sweat glucose monitoring to facilitate diabetes management in a patient-friendly and non-invasive manner. To address this issue, the key challenge lies in the design of flexible sensors with high conductivity, miniaturized patterning, and environmental friendliness. Herein, we introduce a flexible electrochemical sensing system for glucose and pH detection based on one-step laser-scribed PtNPs nanostructured 3D porous laser-scribed graphene (LSG). The as-prepared nanocomposites can synchronously possess hierarchical porous graphene architectures, whereas PtNPs can significantly enhance their sensitivity and electrocatalytic activity. Benefiting from these advantages, the fabricated Pt-HEC/LSG biosensor exhibited a high sensitivity of 69.64 μA mM−1 cm−2 as well as a low limit of detection (LOD) of 0.23 μM at a detection range of 5–3000 μM (covering the glucose range in sweat). Moreover, the pH sensor was functionalized with polyaniline (PANI) on a Pt-HEC/LSG electrode, and it also exhibited high sensitivity (72.4 mV/pH) in the linear range of pH 4–8. The feasibility of the biosensor was confirmed by analyzing human perspiration during physical exercise. This dual-functional electrochemical biosensor displayed excellent performance, including a low detection limit, high selectivity, and great flexibility. These results confirm that the proposed dual-functional flexible electrode and fabrication process are highly promising for application in human sweat-based electrochemical glucose and pH sensors. [Display omitted] •A one-step laser synthesis platinum nanostructured 3D porous graphene.•Platinum nanoparticles were uniformly decorated onto the surface of LSG.•The dual-functional biosensor performed well with excellent flexibility, high sensitivity, high selectivity, and a wide linear range.•The feasibility of the biosensor was successfully demonstrated using human sweat during physical exercise.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2023.124362