Test results of a three phase HTS transformer with double pan cake windings

This paper described construction and test results of a 10 kVA HTS transformer. Three phase transformer with double pancake windings were constructed. BSCCO-2223 wire, silicon sheet steel core and FRP cryostats were used in that transformer. After the test of basic properties of the 3 phase HTS tran...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on applied superconductivity 2002-03, Vol.12 (1), p.808-811
Hauptverfasser: SEUNGWOOK LEE, HEE JOON LEE, GUEESOO CHA, LEE, Ji-Kwang, KYENUNGDAL CHOI, KYUNGWOO RYU, HAHN, Song-Yop
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper described construction and test results of a 10 kVA HTS transformer. Three phase transformer with double pancake windings were constructed. BSCCO-2223 wire, silicon sheet steel core and FRP cryostats were used in that transformer. After the test of basic properties of the 3 phase HTS transformer using no load test, short circuit test and full load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.
ISSN:1051-8223
1558-2515
DOI:10.1109/TASC.2002.1018524