The setting method of the specific parameters of a superconducting fault current limiter installed at the bus-tie and response of protective relays at operation of the SFCL

We have investigated the setting method of specific parameters for a resistance-type and a rectifier-type superconducting fault current limiter (SFCL) installed in trunk transmission lines and the response of protective relays when SFCLs operate against a system fault. This paper describes the setti...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physica. C, Superconductivity Superconductivity, 2002-08, Vol.372, p.1673-1679
Hauptverfasser: Kameda, Hideyuki, Taniguchi, Haruhito
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1679
container_issue
container_start_page 1673
container_title Physica. C, Superconductivity
container_volume 372
creator Kameda, Hideyuki
Taniguchi, Haruhito
description We have investigated the setting method of specific parameters for a resistance-type and a rectifier-type superconducting fault current limiter (SFCL) installed in trunk transmission lines and the response of protective relays when SFCLs operate against a system fault. This paper describes the setting method of specific parameters of an SFCL installed at a bus-tie in a trunk substation, response of protective relays such as bus protection and line protection when the SFCL operates against a system fault and countermeasure of preventing tripping a sound line due to unwanted operation of some distance relays resulted by reverse current at operation of the SFCL.
doi_str_mv 10.1016/S0921-4534(02)01099-7
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_27774283</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0921453402010997</els_id><sourcerecordid>27774283</sourcerecordid><originalsourceid>FETCH-LOGICAL-c433t-9a062b19b3b5e1257e759ac81b0965a93b0c4687249b02f9b092881dc92943a13</originalsourceid><addsrcrecordid>eNqFUctO3DAUtSoqdXh8ApJXFSwCfiTjeIXQqJRKI7GAri3HuSmuMnbq6yDxT3xknZnCtl5cS_eec-7jEHLO2RVnfH39yLTgVd3I-oKJS8aZ1pX6RFa8VbISvJZHZPUB-UKOEX-z8rjmK_L29AwUIWcfftEd5OfY0zjQvGQncH7wjk422VKChEvJUpwnSC6GfnZ72mDnMVM3pwQh09HvfMFSHzDbcYSe2rzX62assgdqQ08T4BQDwiI4pZihKL1ASY_2FRdCLC1s9jG8T_N4t9meks-DHRHO_v0n5Ofdt6fNfbV9-P5jc7utXC1lrrRla9Fx3cmuAS4aBarR1rW8Y3rdWC075up1q0StOyaGErRoW947LXQtLZcn5OtBt4z2ZwbMZufRwTjaAHFGI5RStWhlATYHoEsRMcFgpuR3Nr0azszijdl7Y5bDGybM3hujCu_mwIOyxYuHZNB5CA56n8opTB_9fxT-AgP7mOk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27774283</pqid></control><display><type>article</type><title>The setting method of the specific parameters of a superconducting fault current limiter installed at the bus-tie and response of protective relays at operation of the SFCL</title><source>Access via ScienceDirect (Elsevier)</source><creator>Kameda, Hideyuki ; Taniguchi, Haruhito</creator><creatorcontrib>Kameda, Hideyuki ; Taniguchi, Haruhito</creatorcontrib><description>We have investigated the setting method of specific parameters for a resistance-type and a rectifier-type superconducting fault current limiter (SFCL) installed in trunk transmission lines and the response of protective relays when SFCLs operate against a system fault. This paper describes the setting method of specific parameters of an SFCL installed at a bus-tie in a trunk substation, response of protective relays such as bus protection and line protection when the SFCL operates against a system fault and countermeasure of preventing tripping a sound line due to unwanted operation of some distance relays resulted by reverse current at operation of the SFCL.</description><identifier>ISSN: 0921-4534</identifier><identifier>EISSN: 1873-2143</identifier><identifier>DOI: 10.1016/S0921-4534(02)01099-7</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Distance relay ; Reverse current ; Superconducting fault current limiter</subject><ispartof>Physica. C, Superconductivity, 2002-08, Vol.372, p.1673-1679</ispartof><rights>2002</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c433t-9a062b19b3b5e1257e759ac81b0965a93b0c4687249b02f9b092881dc92943a13</citedby><cites>FETCH-LOGICAL-c433t-9a062b19b3b5e1257e759ac81b0965a93b0c4687249b02f9b092881dc92943a13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0921-4534(02)01099-7$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Kameda, Hideyuki</creatorcontrib><creatorcontrib>Taniguchi, Haruhito</creatorcontrib><title>The setting method of the specific parameters of a superconducting fault current limiter installed at the bus-tie and response of protective relays at operation of the SFCL</title><title>Physica. C, Superconductivity</title><description>We have investigated the setting method of specific parameters for a resistance-type and a rectifier-type superconducting fault current limiter (SFCL) installed in trunk transmission lines and the response of protective relays when SFCLs operate against a system fault. This paper describes the setting method of specific parameters of an SFCL installed at a bus-tie in a trunk substation, response of protective relays such as bus protection and line protection when the SFCL operates against a system fault and countermeasure of preventing tripping a sound line due to unwanted operation of some distance relays resulted by reverse current at operation of the SFCL.</description><subject>Distance relay</subject><subject>Reverse current</subject><subject>Superconducting fault current limiter</subject><issn>0921-4534</issn><issn>1873-2143</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNqFUctO3DAUtSoqdXh8ApJXFSwCfiTjeIXQqJRKI7GAri3HuSmuMnbq6yDxT3xknZnCtl5cS_eec-7jEHLO2RVnfH39yLTgVd3I-oKJS8aZ1pX6RFa8VbISvJZHZPUB-UKOEX-z8rjmK_L29AwUIWcfftEd5OfY0zjQvGQncH7wjk422VKChEvJUpwnSC6GfnZ72mDnMVM3pwQh09HvfMFSHzDbcYSe2rzX62assgdqQ08T4BQDwiI4pZihKL1ASY_2FRdCLC1s9jG8T_N4t9meks-DHRHO_v0n5Ofdt6fNfbV9-P5jc7utXC1lrrRla9Fx3cmuAS4aBarR1rW8Y3rdWC075up1q0StOyaGErRoW947LXQtLZcn5OtBt4z2ZwbMZufRwTjaAHFGI5RStWhlATYHoEsRMcFgpuR3Nr0azszijdl7Y5bDGybM3hujCu_mwIOyxYuHZNB5CA56n8opTB_9fxT-AgP7mOk</recordid><startdate>20020801</startdate><enddate>20020801</enddate><creator>Kameda, Hideyuki</creator><creator>Taniguchi, Haruhito</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20020801</creationdate><title>The setting method of the specific parameters of a superconducting fault current limiter installed at the bus-tie and response of protective relays at operation of the SFCL</title><author>Kameda, Hideyuki ; Taniguchi, Haruhito</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c433t-9a062b19b3b5e1257e759ac81b0965a93b0c4687249b02f9b092881dc92943a13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Distance relay</topic><topic>Reverse current</topic><topic>Superconducting fault current limiter</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kameda, Hideyuki</creatorcontrib><creatorcontrib>Taniguchi, Haruhito</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Physica. C, Superconductivity</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kameda, Hideyuki</au><au>Taniguchi, Haruhito</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The setting method of the specific parameters of a superconducting fault current limiter installed at the bus-tie and response of protective relays at operation of the SFCL</atitle><jtitle>Physica. C, Superconductivity</jtitle><date>2002-08-01</date><risdate>2002</risdate><volume>372</volume><spage>1673</spage><epage>1679</epage><pages>1673-1679</pages><issn>0921-4534</issn><eissn>1873-2143</eissn><abstract>We have investigated the setting method of specific parameters for a resistance-type and a rectifier-type superconducting fault current limiter (SFCL) installed in trunk transmission lines and the response of protective relays when SFCLs operate against a system fault. This paper describes the setting method of specific parameters of an SFCL installed at a bus-tie in a trunk substation, response of protective relays such as bus protection and line protection when the SFCL operates against a system fault and countermeasure of preventing tripping a sound line due to unwanted operation of some distance relays resulted by reverse current at operation of the SFCL.</abstract><pub>Elsevier B.V</pub><doi>10.1016/S0921-4534(02)01099-7</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0921-4534
ispartof Physica. C, Superconductivity, 2002-08, Vol.372, p.1673-1679
issn 0921-4534
1873-2143
language eng
recordid cdi_proquest_miscellaneous_27774283
source Access via ScienceDirect (Elsevier)
subjects Distance relay
Reverse current
Superconducting fault current limiter
title The setting method of the specific parameters of a superconducting fault current limiter installed at the bus-tie and response of protective relays at operation of the SFCL
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T15%3A06%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20setting%20method%20of%20the%20specific%20parameters%20of%20a%20superconducting%20fault%20current%20limiter%20installed%20at%20the%20bus-tie%20and%20response%20of%20protective%20relays%20at%20operation%20of%20the%20SFCL&rft.jtitle=Physica.%20C,%20Superconductivity&rft.au=Kameda,%20Hideyuki&rft.date=2002-08-01&rft.volume=372&rft.spage=1673&rft.epage=1679&rft.pages=1673-1679&rft.issn=0921-4534&rft.eissn=1873-2143&rft_id=info:doi/10.1016/S0921-4534(02)01099-7&rft_dat=%3Cproquest_cross%3E27774283%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=27774283&rft_id=info:pmid/&rft_els_id=S0921453402010997&rfr_iscdi=true