The effect of change in flow rate on the vibration of double-suction centrifugal pumps

Abstract This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that wil...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Proceedings of the Institution of Mechanical Engineers. Part E, Journal of process mechanical engineering Journal of process mechanical engineering, 2002-01, Vol.216 (1), p.47-58
Hauptverfasser: Hodkiewicz, M R, Norton, M P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that will assist in identifying low flow conditions in double-suction pumps.