The effect of change in flow rate on the vibration of double-suction centrifugal pumps
Abstract This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that wil...
Gespeichert in:
Veröffentlicht in: | Proceedings of the Institution of Mechanical Engineers. Part E, Journal of process mechanical engineering Journal of process mechanical engineering, 2002-01, Vol.216 (1), p.47-58 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that will assist in identifying low flow conditions in double-suction pumps. |
---|---|
ISSN: | 0954-4089 2041-3009 |
DOI: | 10.1243/095440802760075030 |