Magnetic prestressing for a d32-mode single crystal ultrasonic transducer

This work describes a 35.9 kHz ultrasonic transducer that incorporates a magnetic arrangement to apply a static-compressive prestress to a d32-mode relaxor ferroelectric single crystal drive-element. The magnetic arrangement produces a 22.5 N static-compressive force, inducing a static compression o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 2023-01, Vol.153 (1), p.7-16
Hauptverfasser: Moss, Scott D., Flicker, Jess D., Munk, David J., Schipper, Matthew J., Smithard, Joel, Jung, George, Hills, Zane, Hou, Jianfu, Daniels, John E., Finkel, Peter
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This work describes a 35.9 kHz ultrasonic transducer that incorporates a magnetic arrangement to apply a static-compressive prestress to a d32-mode relaxor ferroelectric single crystal drive-element. The magnetic arrangement produces a 22.5 N static-compressive force, inducing a static compression of ∼630 nm on the drive-element. Operating in air with a continuous-wave 10 V peak drive at ∼35.9 kHz, the measured resonant peak displacement of the transducers head-mass was 127 nm. This is well within the predicted static compression, thus, the drive-element is protected from damaging tensile stress. Under the same drive conditions and at an axial distance of 10 mm from the face of the head-mass, the measured acoustic pressure was ∼12 Pa. Analytical and finite element model predictions and the measured behaviour of a prototype device are presented and show good correlation, demonstrating that magnetic prestressing of the drive-element can be a viable alternative to the traditional bolt-clamp.
ISSN:0001-4966
1520-8524
DOI:10.1121/10.0016754