A Comparison of Percutaneous Pedicle Screw Accuracy Between Robotic Navigation and Novel Fluoroscopy-Based Instrument Tracking for Patients Undergoing Instrumented Thoracolumbar Surgery
The accuracy of pedicle screws placed with instrument tracking and robotic navigation are individually comparable or superior to placement using standard fluoroscopy, however head-to-head comparisons between these adjuncts in a similar surgical population have yet to be performed. Consecutive patien...
Gespeichert in:
Veröffentlicht in: | World neurosurgery 2023-04, Vol.172, p.e389-e395 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The accuracy of pedicle screws placed with instrument tracking and robotic navigation are individually comparable or superior to placement using standard fluoroscopy, however head-to-head comparisons between these adjuncts in a similar surgical population have yet to be performed.
Consecutive patients undergoing percutaneous thoracic and lumbosacral spinal instrumentation were retrospectively enrolled. Instrumentation was performed using either fluoroscopy-based instrument tracking system (TrackX, TrackX Technologies) or robotic-navigation (ExcelsiusGPS, Globus Medical). Postinstrumentation computed tomography scans were graded for breach according to the Gertzbein-Robbins scale, with “acceptable” screws deemed as Grade A or B and “unacceptable” screws deemed as Grades C through E. Accuracy data was compared between both instrumentation modalities.
Fifty-three patients, comprising a total of 250 screws (167 robot, 83 instrument tracking) were included. The overall accuracy between both modalities was similar, with 96.4% and 97.6% of screws with acceptable accuracy between instrument tracking and robotic navigation, respectively (I-squared 0.30, df = 1, P = 0.58). Between instrument tracking and robotic navigation, 92.8% and 95.8% of screws received Grade A, 3.6% and 1.8% a Grade B, 1.2% and 1.2% a Grade C, 1.2% and 0.6% a Grade D, and 1.2% and 0.6% a Grade E, respectively. The robot was abandoned intraoperatively in 2 cases due to unrecoverable registration inaccuracy or software failure, leading to abandonment of 8 potential screws (4.8%).
In a similar patient population, there is a similarly high degree of instrumentation accuracy between fluoroscopy-based instrument tracking and robotic navigation. There is a rare chance for screw breach with either surgical adjunct. |
---|---|