Benchmarking of stray neutron fields produced by synchrocyclotrons and synchrotrons in compact protontherapy centers (CPTC) using MCNP6 Monte Carlo code

Proton therapy is an external radiotherapy using proton beams with energies between 70 and 230 MeV to treat some type of tumours with outstanding benefits, due to its energy transfer plot. There is a growing demand of facilities taking up small spaces and Compact Proton Therapy Centers (CPTC), with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2023-03, Vol.193, p.110645-110645, Article 110645
Hauptverfasser: García-Fernandez, Gonzalo F., Gallego, Eduardo, Gómez-Ros, José M., Vega-Carrillo, Héctor R., Guzman-García, Karen A., Cevallos-Robalino, Lenin E., García-Baonza, Roberto, Fuentes Hernández, Eduardo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Proton therapy is an external radiotherapy using proton beams with energies between 70 and 230 MeV to treat some type of tumours with outstanding benefits, due to its energy transfer plot. There is a growing demand of facilities taking up small spaces and Compact Proton Therapy Centers (CPTC), with one or two treatment rooms, supposing the technical response of manufacturers to this request. A large amount of stray radiation is yielded in the interaction of proton beam used in therapy, neutrons mainly, hence, optimal design of shielding and verifications must be carried out in commissioning phases. Currently, almost 50 proton centers are under construction and start up in several countries, including ten in Spain. In the present work the effectiveness of shielding in two CPTC was verified with the Monte Carlo code MCNP6 by calculating the ambient dose equivalent, H*(10) due to secondary neutrons, outside the enclosures and walls of the center. The facilities modelled were the two centers currently operating in Spain, the first, since December 2019, with a superconductor synchrocyclotron, and the second, since March 2020, with a compact synchrotron. The geometry and materials are based on dimensions proposed a priori by the vendors, therefore, the paper is focused on check the suitability of the materials and thickness of the walls of the centers. Several models of the radiation sources were simulated, starting from a conservative assumptions, followed by more realistic scenarios. In all cases, the results reached for the ambient dose equivalent, H*(10), were below 1 mSv/year, which is the legal limit considered for the public in international references. Finally, considering that the recent ICRU Report 95 proposes changes in the operational quantities, the dose outside shieldingt has been evaluated in terms of the new next area surveillance quantity, H*, known as ambient dose, in the process of implementation. •Compact Proton Therapy Centers (CPTC) are a new trend in the development of proton facilities.•Benchmarking of ambient dose equivalent, H*(10), and ambient dose, H*, in CPTC, was carried out through MCNP6.2 code.•CPTC benchmarked were those with compact synchrocyclotrons and with compact synchrotrons operating in Spain in 2020.•Different scenarios and materials in barriers were considered in the assessment of shielding of CPTC.
ISSN:0969-8043
1872-9800
DOI:10.1016/j.apradiso.2022.110645